Audio Snake Cable, 24-24 AWG bare copper pairs, polyolefin insulation, individually shielded with double serve "French Braid", drain, numbered/color-coded PVC jackets, flexible PVC jacket
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs | 
|---|
| 24 | 41x40 | BC - Bare Copper | 0.0225 in | 24 | 
| Conductor Count | 48 | 
|---|
| Total Number of Pairs | 24 | 
|---|
Insulation
| Material | Nominal Diameter | Nominal Wall Thickness | 
|---|
| PP - Polypropylene | 0.04 in | 0.008 in | 
Color Chart
| Number | Color | 
|---|
| 1 | Brown | 
| 2 | Red | 
| 3 | Orange | 
| 4 | Yellow | 
| 5 | Green | 
| 6 | Blue | 
| 7 | Purple | 
| 8 | Gray | 
| 9 | White | 
| 10 | Black | 
| 11 | Tan | 
| 12 | Pink | 
| 13 | Gray/Brown | 
| 14 | Gray/Red | 
| 15 | Gray/Orange | 
| 16 | Gray/Yellow | 
| 17 | Gray/Green | 
| 18 | Gray/Blue | 
| 19 | Gray/Purple | 
| 20 | Gray/Gray | 
| 21 | Gray/White | 
| 22 | Gray/Black | 
| 23 | Gray/Tan | 
| 24 | Gray/Pink | 
Color Chart 2
Inner Shield
| Type | Material | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D | 
|---|
| French Braid | Bare Copper (BC) | 95% | TC - Tinned Copper | 0.025 in | 24 | 19x26 | 
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | 
|---|
| PVC - Polyvinyl Chloride | 0.119 in | 0.014 in | 
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | 
|---|
| PVC - Polyvinyl Chloride | 0.825 in | 0.09 in | 
Construction and Dimensions
Stranding
Electrical Characteristics
Conductor DCR
| Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | 
|---|
| 7.2 Ohm/1000ft | 25.5 Ohm/1000ft | 25.5 Ohm/1000ft | 
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | 
|---|
| 26.1 pF/ft | 47.5 pF/ft | 
Inductance
| Nominal Inductance | 
|---|
| 0.18 µH/ft | 
Impedance
| Nominal Characteristic Impedance | 
|---|
| 60 Ohm | 
Delay
| Nominal Velocity of Propagation (VP) [%] | 
|---|
| 66% | 
Current
| Max. Recommended Current [A] | 
|---|
| 1.05 Amps per Conductor at 25ºC | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V RMS | 
Temperature Range
| Operating Temperature Range | -20°C To +60°C | 
|---|
Mechanical Characteristics
| Bulk Cable Weight | 397 lbs/1000ft | 
|---|
| Max. Pull Tension | 700 lbs | 
|---|
| Min. Bend Radius/Minor Axis | 8.25 in | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) | 
|---|
| EU Directive 2000/53/EC (ELV) | Yes | 
|---|
| EU Directive 2003/11/EC (BFR) | Yes | 
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes | 
|---|
| EU Directive 2012/19/EU (WEEE) | Yes | 
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes | 
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) | 
|---|
| EU CE Mark | No | 
|---|
| MII Order #39 (China RoHS) | Yes | 
|---|
Suitability
Flammability, LS0H, Toxicity Testing
| UL voltage rating | 300 V RMS | 
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. | 
|---|
History
| Update and Revision | Revision Number: 0.347    Revision Date: 11-09-2022 | 
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets