Electronic, 3 Conductor 18AWG (16x30) Tinned Copper, PO Insulation, Overall Beldfoil® Shield, PVC Outer Jacket
Specifications
Specifications
Product Overview
Suitable Applications | Electronics |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Conductor(s) | 3 | 18 AWG | 16x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Conductor(s) | PE - Polyethylene | 0.016 in (0.41 mm) | 0.079 in (2.0 mm) | Black, White, Red |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.224 in (5.69 mm) |
Overall Cable Diameter (Nominal) | 0.224 in (5.69 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Max. Current |
---|
Conductor(s) | 7.06 Ohm/1000ft | 13 Amps per Conductor at 30ºC |
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C | -20°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
2.24 in (56.9 mm) | 2.24 in (56.9 mm) |
Max. Pull Tension | 71.5 lbs (32.4 kg) |
---|
Bulk Cable Weight | 30 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Indoor |
---|
Flammability / Reaction to Fire | UL 1685 UL Loading, FT4 |
---|
NEC / UL Compliance | Article 800, CM |
---|
AWM Compliance | AWM 2093 |
---|
CEC / C(UL) Compliance | HLABCD, ACIC |
---|
History
Update and Revision | Revision Number: 0.36 Revision Date: 01-23-2023 |
---|
Documentation
Product Bulletins
Data Sheets