Fieldbus, 1 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, Orange TPE Outer Jacket, CMG
Specifications
Specifications
Product Overview
Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
---|
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | No. of Pairs |
---|
Pair(s) | 18 | 7x26 | TC - Tinned Copper | 1 |
Conductor Count | 2 |
---|
Total Number of Pairs | 1 |
---|
Insulation
Material |
---|
XLPE - Cross-Linked Polyethylene (Thermoset) |
Color Chart
Number | Color |
---|
1 | Blue, Orange and Numbered |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 20 | 7x28 |
| Tinned Copper (TC) | | | | |
Outer Shield
Material |
---|
Bi-Laminate (Alum+Poly) |
Outer Jacket
Material | Nominal Diameter | Ripcord |
---|
TPE - Thermoplastic Elastomer | 0.319 in | Yes |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
5.86 Ohm/1000ft |
Capacitance
Max. Capacitance Unbalance | Nom. Capacitance Conductor to Shield |
---|
1.2 pF/ft | 22 pF/ft |
Inductance
Nominal Inductance |
---|
0.22 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
100 Ohm |
High Frequency (Nominal/Typical)
Nom. Insertion Loss |
---|
0.08 dB/100ft |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
64% |
High Frequency
Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) |
---|
0.091 dB/100ft | 100 Ohm |
Current
Element | Max. Recommended Current [A] |
---|
Per Conductor | 8.7 Amps per Conductor |
Voltage
Description | UL Voltage Rating | Voltage Rating [V] |
---|
CSA CIC type TC | 300 V | 300 V RMS |
Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
---|
Other Electrical Characteristic 2 | 31.25 KBits/sec |
---|
Temperature Range
Installation Temp Rating | -25°C |
---|
Installation Temperature Range | -25°C |
---|
UL Temp Rating | 90°C Wet/Dry |
---|
Operating Temperature Range | -25°C Cold Impact -40°C to +90°C -55°C Cold Bend |
---|
Mechanical Characteristics
UV Resistance | Yes |
---|
Bulk Cable Weight | 51 lbs/1000ft |
---|
Max. Pull Tension | 57 lbs |
---|
Min. Bend Radius/Minor Axis | 3.25 in |
---|
Standards
NEC Articles | Article 725, Article 727, Article 800 |
---|
NEC/(UL) Compliance | CMG, ITC, PLTC-ER |
---|
CSA AWM Compliance | AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Oil Resistance | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 FT4 Loading |
---|
IEC Flammability | IEC 60332-3-24 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.479 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets