Fieldbus, 50 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Individual & Overall Beldfoil® Shield, Orange TPE Outer Jacket, CMG
Specifications
Specifications
Product Overview
Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
---|
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | No. of Pairs |
---|
Pair(s) | 18 | 7x26 | TC - Tinned Copper | 50 |
Insulation
Material | Nominal Wall Thickness |
---|
XLPE - Cross-Linked Polyethylene (Thermoset) | 0.032 in |
Color Chart
Number | Color |
---|
1 | Blue, Orange and Numbered |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 20 | 7x28 |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 18 | 7x26 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
---|
TPE - Thermoplastic Elastomer | 1.947 in | 0.12 in | Yes |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
5.86 Ohm/1000ft |
Capacitance
Max. Capacitance Unbalance | Nom. Capacitance Conductor to Conductor |
---|
1.2 pF/ft | 22 pF/ft |
Inductance
Nominal Inductance |
---|
0.22 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
120 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
0.039 MHz | 0.08 dB/100ft |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
64% |
High Frequency
Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) |
---|
0.091 dB/100ft | 100 Ohm |
Current
Element | Max. Recommended Current [A] |
---|
Per Conductor | 5.4 Amps per Conductor |
Voltage
Description | UL Voltage Rating |
---|
CSA CIC type TC | 300 V |
Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
---|
Other Electrical Characteristic 2 | 31.25 KBits/sec |
---|
Temperature Range
Installation Temp Rating | -25°C |
---|
UL Temp Rating | 90°C |
---|
Operating Temperature Range | -40°C to 90°C |
---|
Mechanical Characteristics
Oil Resistance | Yes |
---|
Bulk Cable Weight | 1782 lbs/1000ft |
---|
Max. Pull Tension | 2892 lbs |
---|
Min. Bend Radius/Minor Axis | 19.5 in |
---|
Standards
NEC Articles | Article 725, Article 727, Article 800 |
---|
NEC/(UL) Compliance | CMG, ITC, PLTC-ER |
---|
CEC/C(UL) Compliance | CIC, TC |
---|
CSA AWM Compliance | AWM I A/B II A/B |
---|
ISO/IEC Compliance | IEC 61158-2 |
---|
Other Standards | ISA/SP-50 Type A |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Oil Resistance | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
IEC Flammability | IEC 60332-3-24 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.268 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets