Belden
2127A - Fieldbus, 1 Pr #16 Str TC, XLPE Ins, OS, TPE Jkt, 600V TC
- SKU:
- 2127A
- Shipping:
- Calculated at Checkout
Description
Fieldbus, 1 Pair 16AWG (7x24) Tinned Copper, XLPE Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, 600V TC
Specifications
Specifications
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 1 | 16 AWG | 7x24 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Pair(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.038 in (0.97 mm) | 0.135 in (3.43 mm) | Blue, Orange and Numbered |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 18 AWG (7x26) TC |
Outer Jacket
| Separator | Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|---|
| Polyester Tape | TPE - Thermoplastic Elastomer | 0.047 in (1.2 mm) | 0.374 in (9.50 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.374 in (9.50 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Max. Capacitance Unbalance | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|
| Pair(s) | 4.5 Ohm/1000ft | 1.2 pF/ft (3.9 pF/m) | 22 pF/ft | 100 Ohm | 64% | 11.6 Amps per Conductor at 25ºC |
| Nom. Outer Shield DCR | 5.1 Ohm/1000ft (17 Ohm/km) |
|---|
High Frequency (Nominal/Typical)
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|---|---|
| Pair(s) | 0.039 | 0.065 dB/100ft |
High Frequency
| Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) [Ohm] |
|---|---|
| 0.091 dB/100ft | 100 |
Voltage
| UL Voltage Rating |
|---|
| 600 V |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 90°C | -40°C to +90°C Wet/Dry |
| Table Notes | -40C |
|---|
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 3.75 in (95.3 mm) | 3.75 in (95.3 mm) |
| Max. Pull Tension | 93 lbs (42 kg) |
|---|---|
| Bulk Cable Weight | 67 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
|---|---|
| Flammability / Reaction to Fire | UL 1581 Vertical Tray, FT4, IEEE 1202, IEC 60332-3-24 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | Article 336, ITC-ER, PLTC-ER |
| AWM Compliance | AWM I/II A/B |
| CEC / C(UL) Compliance | CIC, TC |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| Other Standard Compliance(s) | ISA/SP-50 Type A |
History
| Update and Revision | Revision Number: 0.521 Revision Date: 06-01-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC |
Variant_Options 2127A 0061000: |
2127A 0061000|Blue, Light|Reel|1,000 ft|612825129943 |
Variant_Options 2127A 0065000: |
2127A 0065000|Blue, Light|Reel|5,000 ft|612825129950 |
Variant_Options 2127A 0035000: |
2127A 0035000|Orange|Reel|5,000 ft|612825129936 |