Belden

2129A - Fieldbus, 5 Pr #16 Str TC, XLPE Ins, IS/OS, TPE Jkt, 600V TC-ER

(No reviews yet) Write a Review
SKU:
2129A
Shipping:
Calculated at Checkout
$0.00

Description

Fieldbus, 5 Pair 16AWG (7x24) Tinned Copper, XLPE Insulation, Individual & Overall Beldfoil® Shield, TPE Outer Jacket, 600V TC-ER

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)516 AWG7x24TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessColor Code
Pair(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.038 in (0.97 mm)Blue, Orange and Numbered

Inner Shield

ElementShield TypeMaterialCoverageDrainwire TypeNotes
Pair(s)TapeBi-Laminate (Alum+Poly)100%18 AWG (7x26) TCIndividually Shielded

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%16 AWG (7x24) TC

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
TPE - Thermoplastic Elastomer0.063 in (1.6 mm)0.789 in (20.0 mm)Yes
Overall Cable Diameter (Nominal)0.789 in (20.0 mm)

Electrical Characteristics

Electricals

Nom. Conductor DCRMax. Capacitance UnbalanceNom. Capacitance Cond-to-CondNom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
4.2 Ohm/1000ft (14 Ohm/km)1.2 pF/ft (3.9 pF/m)22 pF/ft (72 pF/m)100 Ohm64%10.1 Amps per Conductor

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss (Attenuation)
0.0390.065 dB/100ft

High Frequency

Max. Insertion Loss (Attenuation)Max./Min. Input Impedance (unFitted)
0.091 dB/100ft100 Ohm

Voltage

UL Voltage Rating
600 V (TC-ER), 600 V (CSA CIC Type TC)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Wet/Dry-40°C to 90°C
Table Notes-40C
Max. Pull Tension504 lbs (229 kg)
Bulk Cable Weight294 lbs/1000ft (438 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Flammability / Reaction to FireUL1581 Vertical Tray, IEC 60332-3-24
NEC / UL ComplianceArticle 336, TC-ER
AWM ComplianceAWM I A/B II A/B
CEC / C(UL) ComplianceCIC, TC
ISO/IEC ComplianceIEC 61158-2
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)ISA/SP-50 Type A

History

Update and RevisionRevision Number: 0.442 Revision Date: 05-05-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 2129A 0061000:
2129A 0061000|Blue, Light|Reel|1,000 ft|612825130109
Variant_Options 2129A 0065000:
2129A 0065000|Blue, Light|Reel|5,000 ft|612825130116
Variant_Options 2129A 0031000:
2129A 0031000|Orange|Reel|1,000 ft|612825130086
Variant_Options 2129A 0035000:
2129A 0035000|Orange|Reel|5,000 ft|612825130093
View AllClose