CAT5e (200MHz), 4-Pair, U/UTP-Unshielded, CM-LS Rated, Premise Horizontal OSP Cable, 24 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Gel-filled, UV Resistant Flame Retardant Polyolefin Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | OSP-Outdoor, CM-LS, Low Smoke, Indoor/Outdoor, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 24 | Solid | BC - Bare Copper | 4 |
| Conductor Count | 8 |
|---|
| Total Number of Pairs | 4 |
|---|
Insulation
Color Chart
| Number | Color |
|---|
| 1 | White/Blue Stripe & Blue |
| 2 | White/Orange Stripe & Orange |
| 3 | White/Green Stripe & Green |
| 4 | White/Brown Stripe & Brown |
| Water Penetration | GR 421‐CORE para. 4.3.5.1, ANSI/ICEA S‐107‐704 para. 8.2.1, ANSI/ICEA S-99-689 |
|---|
Outer Jacket
| Material | Material Trade Name | Nominal Diameter | Ripcord |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Haloarrest® | 0.251 in | No |
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | Max. DCR Unbalance |
|---|
| 93.8 Ohm/km | 5.0 % |
Capacitance
| Max. Capacitance Unbalance | Nom.Mutual Capacitance |
|---|
| 330 pF/100m | 15 pF/ft |
Delay
| Frequency [MHz] | Max. Delay | Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
|---|
| 100 MHz | 537.6 ns/100m | 45 ns/100m | 68% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) | Max./Min. Fitted Impedance |
|---|
| 1 MHz | 2.0 dB/100m | 65.3 dB | 62.3 dB | 63.3 dB | 60.3 dB | 63.8 dB | 60.8 dB | 20.0 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 4 MHz | 4.1 dB/100m | 56.3 dB | 53.3 dB | 52.2 dB | 49.2 dB | 51.8 dB | 48.8 dB | 23.0 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 8 MHz | 5.8 dB/100m | 51.8 dB | 48.8 dB | 46.0 dB | 43.0 dB | 45.7 dB | 42.7 dB | 24.5 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 10 MHz | 6.5 dB/100m | 50.3 dB | 47.3 dB | 43.8 dB | 40.8 dB | 43.8 dB | 40.8 dB | 25.0 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 16 MHz | 8.2 dB/100m | 47.2 dB | 44.2 dB | 39.0 dB | 36.0 dB | 39.7 dB | 36.7 dB | 25.0 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 20 MHz | 9.3 dB/100m | 45.8 dB | 42.8 dB | 36.5 dB | 33.5 dB | 37.8 dB | 34.8 dB | 25.0 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 25 MHz | 10.4 dB/100m | 44.3 dB | 41.3 dB | 33.9 dB | 30.9 dB | 35.8 dB | 32.8 dB | 24.3 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 31.25 MHz | 11.7 dB/100m | 42.9 dB | 39.9 dB | 31.2 dB | 28.2 dB | 33.9 dB | 30.9 dB | 23.6 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 62.5 MHz | 17.0 dB/100m | 38.4 dB | 35.4 dB | 21.4 dB | 18.4 dB | 27.9 dB | 24.9 dB | 21.5 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 100 MHz | 22.0 dB/100m | 35.3 dB | 32.3 dB | 13.3 dB | 10.3 dB | 23.8 dB | 20.8 dB | 20.1 dB | 100 ± 15 Ohm | 100 ± 15 Ohm |
| 155 MHz | 28.1 dB/100m | 32.4 dB | 29.4 dB | 4.4 dB | 1.4 dB | 20.0 dB | 17.0 dB | 18.8 dB | | |
| 200 MHz | 32.4 dB/100m | 30.8 dB | 27.8 dB | | | 17.8 dB | 14.8 dB | 18.0 dB | | |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Installation Temperature Range | -20°C To +75°C |
|---|
| UL Temp Rating | 75°C |
|---|
| Storage Temperature Range | -40°C To +75°C |
|---|
| Operating Temperature Range | -40°C To +75°C |
|---|
Mechanical Characteristics
| Cold Bend Test | -20°C Compliance per UL 1581 |
|---|
| Bulk Cable Weight | 35 lbs/1000ft |
|---|
| Max. Pull Tension | 25 lbs |
|---|
| Min. Bend Radius During Installation | 2.5 in |
|---|
| Min. Bend Radius/Minor Axis | 1.0 in |
|---|
Standards
| NEC/(UL) Compliance | CM-LS |
|---|
| CEC/C(UL) Compliance | CM-LS |
|---|
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class D |
|---|
| Data Category | Category 5e |
|---|
| ANSI Compliance | S-90-661-2012 Category 5e, ANSI/NEMA WC-63.1 Category 5e |
|---|
| TIA/EIA Compliance | ANSI/TIA-568-C.2 Category 5e |
|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/96/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
| EU REACH SVHC Compliance (yyyy-mm-dd) | 2017-07-10 |
|---|
Suitability
| Suitability - Aerial | Yes - When supported by messenger wire |
|---|
| Suitability - Burial | Yes - Engineered burial only |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Non-Halogenated | Yes |
|---|
| Suitability - Oil Resistance | No |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL 1685 (UL Loading-Limited Smoke) |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values over 100 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for use in Buildings in Wet Locations. Not Suitable for Direct Burial. Fully Water Blocked and Sunlight Resistant (Black Jacket Only). |
|---|
History
| Update and Revision | Revision Number: 0.319 Revision Date: 12-20-2022 |
|---|
Documentation
Product Bulletins
Warranties
Reference Manuals
Data Sheets