Category 5e Premise Backbone Cable (100MHz), Indoor/Outdoor OSP/CM-LS, 25 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Gel-Filled, Corrugated Aluminum Tape Armor, UV Resistant Flame Retardant Haloarrest® LSZH Outer Jacket
Specifications
Specifications
Product Overview
Suitable Applications | OSP-Outdoor, Indoor/Outdoor, Premise Backbone Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
24 | Solid | BC - Bare Copper | 25 |
Insulation
Material | Color Code |
---|
PO - Polyolefin | Western Electric |
Inner Jacket
Material | Nom. Diameter | Ripcord |
---|
PE - Polyethylene | 0.51 in (13 mm) | Yes |
Armor
Armor Type & Material | Armor Thickness |
---|
CAT - Corrugated Aluminum Tape | .008 in (0.20 mm) |
Outer Jacket
Material | Nom. Diameter | Ripcord |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.730 in (18.5 mm) | Yes |
Overall Cable Diameter (Nominal) | 0.730 in (18.5 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
93.8 Ohm/km (28.6 Ohm/1000ft) | 330 pF/100m |
Delay
Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 68% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. PSNEXT [dB] | Min. RL (Return Loss) [dB] | Max./Min. Fitted Impedance |
---|
1 | 2.0 dB/100m | 62.3 | 20.0 | 100 ± 15% |
4 | 4.1 dB/100m | 53.3 | 23.0 | 100 ± 15% |
8 | 5.8 dB/100m | 48.8 | 24.5 | 100 ± 15% |
10 | 6.5 dB/100m | 47.3 | 25.0 | 100 ± 15% |
16 | 8.2 dB/100m | 44.3 | 25.0 | 100 ± 15% |
20 | 9.3 dB/100m | 42.8 | 25.0 | 100 ± 15% |
25 | 10.4 dB/100m | 41.3 | 24.3 | 100 ± 15% |
31.25 | 11.7 dB/100m | 39.9 | 23.6 | 100 ± 15% |
62.5 | 17.0 dB/100m | 35.4 | 21.5 | 100 ± 15% |
100 | 22.0 dB/100m | 32.3 | 20.1 | 100 ± 15% |
Voltage
UL Voltage Rating |
---|
300 V (CM) |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Installation | Storage |
---|
75°C | -40°C To +75°C | -20°C To +75°C | -40°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
7.5 in (190 mm) | 14.75 in (374.7 mm) |
Max. Pull Tension | 150 lbs (68 kg) |
---|
Bulk Cable Weight | 240 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire |
---|
Flammability / Reaction to Fire | UL 1685 (UL Loading-Limited Smoke) |
---|
NEC / UL Compliance | CM |
---|
CEC / C(UL) Compliance | CM |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3 |
---|
Data Category | Category 5e |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
---|
ISO/IEC Compliance | 11801 ed 2.2 (2011) Class D |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. Not Suitable for Direct Burial. |
---|
History
Update and Revision | Revision Number: 0.370 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Warranties
Reference Manuals
Compliance Documentation
Data Sheets