RG-11/U Triax, 14 AWG solid .064" bare copper conductor, gas-injected foam HDPE insulation, bare copper double shields (95% and 80% coverage), PVC insulation between braids, water blocking tape, CPE jacket, CMR rated
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 14 | Solid | BC - Bare Copper | 0.064 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.285 in |
Inner Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 95% |
Inner Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.365 in |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 80% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| CPE - Chlorinated Polyethylene | 0.475 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Inner Shield DCR | Nominal Outer Shield DCR |
|---|
| 2.6 Ohm/1000ft | 1.7 Ohm/1000ft | 1.5 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 16.1 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.097 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
Return Loss
| Frequency [MHz] | Minimum Return (RL) |
|---|
| 5 - 850 MHz | 21 dB |
| 850 - 4500 MHz | 15 dB |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1.0 MHz | 0.14 dB/100ft |
| 3.6 MHz | 0.3 dB/100ft |
| 10 MHz | 0.4 dB/100ft |
| 71.5 MHz | 1.1 dB/100ft |
| 135 MHz | 1.6 dB/100ft |
| 270 MHz | 2.3 dB/100ft |
| 360 MHz | 2.6 dB/100ft |
| 540 MHz | 3.3 dB/100ft |
| 720 MHz | 3.8 dB/100ft |
| 750 MHz | 4.0 dB/100ft |
| 1000 MHz | 4.6 dB/100ft |
| 1500 MHz | 5.9 dB/100ft |
| 2250 MHz | 7.4 dB/100ft |
| 3000 MHz | 9 dB/100ft |
| 4500 MHz | 12.5 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.21 ns/ft | 84% |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Non-UL Temp Rating | 75°C |
|---|
| UL Temp Rating | 75°C |
|---|
| Operating Temperature Range | -30°C To +75°C |
|---|
Mechanical Characteristics
| UV Resistance | Yes - Black only |
|---|
| Bulk Cable Weight | 125 lbs/1000ft |
|---|
| Max. Pull Tension | 170 lbs |
|---|
| Min. Bend Radius/Minor Axis | 5 in |
|---|
Standards
| NEC/(UL) Compliance | CMR |
|---|
| CPR Euroclass | Eca |
|---|
| RG Type | 11 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/96/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
Suitability
| Suitability - Aerial | Yes - Black only, when supported by messenger wire |
|---|
| Suitability - Burial | No |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes - Black only |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1666 Vertical Shaft |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
|---|
Product Notes
| Notes | Water blocking tape between outer jacket and outer braid. Print legend includes sequential footage marks. |
|---|
History
| Update and Revision | Revision Number: 0.254 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Guide
Data Sheets