Canadian Instrumentation Cable TC-ACIC 300V, 8 Triad 16AWG (7x24) Tinned Copper, XLPE Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, 90C Wet 105C Dry CSA HLBCD SUN RES -40C
Specifications
Specifications
Product Overview
Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Triad(s) | 8 | 16 AWG | 7x24 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Triad(s) | XLP, XLPO, XLPE (Thermoset) | 0.025 in (0.64 mm) | 0.108 in mm | Black, White, Red and Numbered |
Inner Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 16 AWG (7x24) TC |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 18 AWG (7x26) TC |
Inner Jacket
Material | Nom. Thickness | Nom. Diameter | Color |
---|
PVC - Polyvinyl Chloride | 0.083 in (2.1 mm) | 0.937 in (23.8 mm) | Black |
Armor
Armor Type & Material | Armor Thickness | Diameter Over Armor |
---|
AIA - Aluminum Interlock Armor | 1.197 in (30.40 mm) | 1.202 in (30.53 mm) |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.052 in (1.3 mm) | 1.301 in (33.05 mm) | Yes |
Overall Cable Diameter (Nominal) | 1.301 in (33.05 mm) |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Max. Current |
---|
4.6 Ohm/1000ft | 3.03 Ohm/1000ft (9.94 Ohm/km) | 3.2 Amps per Conductor at 30ºC |
Voltage
Mechanical Characteristics
Temperature
Operating |
---|
-40°C To +105°C Dry/90°C Wet |
Bend Radius
Stationary Min. | Installation Min. |
---|
15.612 in (396.54 mm) | 15.612 in (396.54 mm) |
Max. Pull Tension | 1007.8 lbs (457.13 kg) |
---|
Bulk Cable Weight | 794 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance |
---|
CEC / C(UL) Compliance | HLBCD |
---|
History
Update and Revision | Revision Number: 0.58 Revision Date: 01-23-2023 |
---|
Documentation
Product Bulletins
Catalogs
Standards