Belden
2425D - DataTwist 2400 Category 6+ Cable, 4 Pair, U/UTP, LSZH Indoor CPR Eca IEC60332-3-25
- SKU:
- 2425D
- Shipping:
- Calculated at Checkout
Description
Category 6 Enhanced Premise Horizontal Cable (350MHz), 4-Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Polyethylene Insulation, LSZH Jacket IEC60332-3-25
Specifications
Specifications
Product Overview
Suitable Applications | Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM |
---|
Construction Details
Conductor
Element | Size | Stranding | Material | Number of Pairs | Number of Element |
---|---|---|---|---|---|
Individual Pair | 24 AWG | Solid | BC - Bare Copper | 4 | 8 |
Insulation
Element | Material | Nom. Insulation Diameter | Color Code |
---|---|---|---|
Individual Pair | PE - Polyethylene | 1 mm (0.039 in) | White/Blue & Blue, White/Orange & Orange, White/Green & Green, White/Brown & Brown |
Cable Core
Description |
---|
4 pairs twisted together |
Outer Jacket
Material | Nom. Diameter | Ripcord |
---|---|---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6.6 mm (0.26 in) | Yes |
Overall Cable Diameter (Nominal) | 6.6 mm (0.26 in) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|---|---|---|
93.8 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
Delay
Max. Delay Skew | Nom. Velocity of Prop. |
---|---|
35 ns/100m | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 dB/100m | 75.3 | 73.3 | 73.3 | 71.3 | 70.8 | 67.8 | 20 | 40 | 35 |
4 | 3.7 dB/100m | 66.3 | 64.3 | 62.6 | 60.6 | 58.8 | 55.8 | 23 | 40 | 23 |
10 | 5.8 dB/100m | 61.8 | 59.8 | 56 | 54 | 50.8 | 47.8 | 25 | 40 | 15 |
16 | 7.4 dB/100m | 58.6 | 56.6 | 51.2 | 49.2 | 46.7 | 43.7 | 25 | 38 | 10.9 |
20 | 8.3 dB/100m | 57.1 | 55.1 | 48.8 | 46.8 | 44.8 | 41.8 | 25 | 37 | 9 |
31.2 | 10.4 dB/100m | 54 | 52 | 43.6 | 41.6 | 40.9 | 37.9 | 23.6 | 35.1 | 5.1 |
62.5 | 15 dB/100m | 49.1 | 47.1 | 34.1 | 32.1 | 34.9 | 31.9 | 21.5 | 32.6 | |
100 | 19.3 dB/100m | 45.8 | 43.8 | 26.5 | 24.5 | 30.8 | 27.8 | 20.8 | 30 | |
200 | 28.3 dB/100m | 40.9 | 38.9 | 12.6 | 10.6 | 22.8 | 21.8 | 19.5 | 27 | |
250 | 32.1 dB/100m | 39.3 | 37.3 | 7.2 | 5.2 | 22.8 | 19.8 | 18 | 26.0 | |
300 | 35.6 dB/100m | 38.1 | 36.1 | 2.5 | 0.5 | 21.3 | 18.3 | 17.5 | 25.2 | |
350 | 38.8 dB/100m | 37.1 | 35.1 | 19.9 | 16.9 | 17.0 | 24.6 |
Table Notes | Limits below 4 MHz are for information only. Reference standard: IEC 61156-5 |
---|
Voltage
Voltage Rating |
---|
72 V DC |
Mechanical Characteristics
Temperature
Operating | Installation |
---|---|
-20°C to +75°C | 0°C To +50°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
26 mm (1.0 in) | 52 mm |
Max. Pull Tension | 80 N (18 lbf) |
---|---|
Bulk Cable Weight | 52 kg/km |
Standards and Compliance
Environmental Suitability | Indoor - Euroclass Eca |
---|---|
Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-2-25 |
CPR Compliance | CPR Euroclass: Eca |
IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
Data Category | Category 6 |
TIA/EIA Compliance | ANSI/TIA 568.2-D |
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61034-2 - Smoke Density Min Transmittance = 60% |
CENELEC Compliance | EN 50173-1, Segregation class according EN50174-2 = a |
European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
European Directive Compliance | EU CE Mark |
UK Regulation Compliance | UKCA Mark |
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
---|
History
Update and Revision | Revision Number: 0.279 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
- DataTuff Fiber Optic Renewable Grade Cable
- Belden Outside Plant Indoor/Outdoor Cables
- Belden Cable Prep Tool Instructions
- Blade Slot Selection Table
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|EAN |
Variant_Options 2425D.06305: |
2425D.06305|Blue|Reel|305 m|8719605005328 |
Variant_Options 2425D.K6305: |
2425D.K6305|Blue|Reel|305 m|8719605147837 |
Variant_Options 2425D.06500: |
2425D.06500|Blue|Reel|500 m|8719605005335 |
Variant_Options 2425D.K6500: |
2425D.K6500|Blue|Reel|500 m|8719605147844 |
Variant_Options 2425D.061000: |
2425D.061000|Blue|Reel|1,000 m|8719605005311 |
Variant_Options 2425D.08305: |
2425D.08305|Gray|Reel|305 m|8719605141354 |
Variant_Options 2425D.08500: |
2425D.08500|Gray|Reel|500 m|8719605005366 |
Variant_Options 2425D.K8500: |
2425D.K8500|Gray|Reel|500 m|8719605147851 |
Variant_Options 2425D.07305: |
2425D.07305|Purple|Reel|305 m|8719605005359 |
Variant_Options 2425D.071000: |
2425D.071000|Purple|Reel|1,000 m|8719605005342 |