Description

Category 6+ Enhanced Premise Horizontal Cable (350MHz), 4 Bonded-Pairs, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, Flamarrest® PVC-LS Jacket

Specifications

Specifications

Product Overview

Suitable ApplicationsPremise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
23SolidBC - Bare Copper4
Conductor Count8
Total Number of Pairs4

Insulation

Material
FEP - Fluorinated Ethylene Propylene
Bonded-PairN/A

Color Chart

NumberColor
1White/Blue Stripe & Blue
2White/Orange Stripe & Orange
3White/Green Stripe & Green
4White/Brown Stripe & Brown

Outer Jacket

MaterialMaterial Trade NameNominal DiameterRipcord
PVC - Polyvinyl ChlorideFlamarrest®0.224 inYes

Electrical Characteristics

Conductor DCR

Max. Conductor DCRMax. DCR Unbalance
78 Ohm/km3.0 %

Capacitance

Max. Capacitance UnbalanceNom.Mutual Capacitance
330 pF/100m17 pF/ft

Delay

Max. DelayMax. Delay SkewNominal Velocity of Propagation (VP) [%]
537.6 ns/100m35 ns/100m72%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXTMin. PSAACRF
1 MHz2.0 dB/100m79.3 dB77.3 dB77.3 dB75.3 dB70.8 dB67.8 dB20.0 dB100 ± 15102 ± 1577.0 dB67.0 dB
4 MHz3.7 dB/100m70.3 dB68.3 dB66.5 dB64.5 dB58.8 dB55.8 dB23.6 dB100 ± 15100 ± 1577.0 dB66.2 dB
8 MHz5.3 dB/100m65.8 dB63.8 dB60.5 dB58.5 dB52.7 dB49.7 dB25.3 dB100 ± 15100 ± 1577.0 dB60.1 dB
10 MHz5.9 dB/100m64.3 dB62.3 dB58.4 dB56.4 dB50.8 dB47.8 dB26.0 dB100 ± 15100 ± 1577.0 dB58.2 dB
16 MHz7.4 dB/100m61.2 dB59.2 dB53.8 dB51.8 dB46.7 dB43.7 dB26.0 dB100 ± 15100 ± 1574.4 dB54.1 dB
20 MHz8.3 dB/100m59.8 dB57.8 dB51.4 dB49.4 dB44.8 dB41.8 dB26.0 dB100 ± 15100 ± 1573.0 dB52.2 dB
25 MHz9.4 dB/100m58.3 dB56.3 dB49.0 dB47.0 dB42.8 dB39.8 dB25.5 dB100 ± 15100 ± 1571.5 dB50.2 dB
31.25 MHz10.5 dB/100m56.9 dB54.9 dB46.4 dB44.4 dB40.9 dB37.9 dB25.0 dB100 ± 15100 ± 1570.1 dB48.3 dB
62.5 MHz15.1 dB/100m52.4 dB50.4 dB37.3 dB35.3 dB34.9 dB31.9 dB23.5 dB100 ± 15100 ± 1565.6 dB42.3 dB
100 MHz19.3 dB/100m49.3 dB47.3 dB30.0 dB28.0 dB30.8 dB27.8 dB22.5 dB100 ± 15100 ± 1562.5 dB38.2 dB
155 MHz24.5 dB/100m46.4 dB44.4 dB21.9 dB19.9 dB27.0 dB24.0 dB21.6 dB100 ± 22100 ± 1558.0 dB32.2 dB
200 MHz28.3 dB/100m44.8 dB42.8 dB16.6 dB14.6 dB24.8 dB21.8 dB21.0 dB100 ± 22100 ± 1556.5 dB30.2 dB
250 MHz31.8 dB/100m43.3 dB41.3 dB11.5 dB9.5 dB22.8 dB19.8 dB20.5 dB100 ± 32100 ± 1555.3 dB28.7 dB
300 MHz35.2 dB/100m42.1 dB40.1 dB6.9 dB4.9 dB21.3 dB18.3 dB20.1 dB100 ± 32100 ± 1554.3 dB27.3 dB
350 MHz38.4 dB/100m41.1 dB39.1 dB2.7 dB0.7 dB19.9 dB16.9 dB19.8 dB100 ± 32100 ± 1553.5 dB26.2 dB
400 MHz41.5 dB/100m40.3 dB38.3 dB18.8 dB15.8 dB19.5 dB100 ± 32100 ± 1552.7 dB25.1 dB
450 MHz44.3 dB/100m39.5 dB37.5 dB17.7 dB14.7 dB19.2 dB100 ± 32100 ± 1552.0 dB24.2 dB
500 MHz47.1 dB/100m38.8 dB36.8 dB16.8 dB13.8 dB19.0 dB100 ± 32100 ± 15
550 MHz49.7 dB/100m38.2 dB36.2 dB16.0 dB13.0 dB18.8 dB100 ± 32100 ± 15

Voltage

UL Voltage Rating
300 V RMS

Temperature Range

Installation Temperature Range0°C To +50°C
UL Temp Rating90°C
Storage Temperature Range-20°C To +75°C
Operating Temperature Range-20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight26 lbs/1000ft
Max. Pull Tension25 lbs
Min. Bend Radius/Minor Axis1.0 in

Standards

NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP
ISO/IEC Compliance11801 ed 2.2 (2011) Class E
CPR EuroclassEca
Data CategoryCategory 6
ANSI ComplianceS-116-732-2013 Category 6, ANSI/NEMA WC-66 Category 6
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Third Party Performance VerificationCategory 6

Applicable Environmental and Other Programs

Environmental SpacePlenum
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceYes
EU CE MarkYes
EU REACH SVHC Compliance (yyyy-mm-dd)2017-07-10

Suitability

Suitability - AerialNo
Suitability - BurialNo
Suitability - Hazardous LocationsNo
Suitability - IndoorYes
Suitability - Non-HalogenatedNo
Suitability - Oil ResistanceNo
Suitability - OutdoorNo
Suitability - Sunlight ResistanceNo

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262 Plenum (UL 910)
IEC FlammabilityIEC 60332-1-2

Plenum/Non-Plenum

Plenum (Y/N)Yes

Related Part Numbers

Non-Plenum Number2432

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.

History

Update and RevisionRevision Number: 0.131 Revision Date: 12-20-2022