4 Pair 22 AWG stranded (7x30) TC conductor, polyolefin insulation, individually shielded with bonded Beldfoil®, numbered/color-coded PVC jackets, jackets and shields are bonded so both strip simultaneously, water blocking tape, overall black CPE jacket and nylon rip cord.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
22 | 7x30 | TC - Tinned Copper | 0.029 in | 4 |
Insulation
Material | Nominal Diameter |
---|
PP - Polypropylene | 0.05 in |
Color Chart
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 |
Inner Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.133 in |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 18 |
Outer Jacket
Material | Nominal Diameter |
---|
CPE - Chlorinated Polyethylene | 0.432 in |
Electrical Characteristics
Conductor DCR
Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
14.1 Ohm/1000ft | 14.8 Ohm/1000ft | 11.8 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
31 pF/ft | 56 pF/ft |
Inductance
Nominal Inductance |
---|
0.18 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
66% |
Current
Max. Recommended Current [A] |
---|
1.45 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 75°C |
---|
Operating Temperature Range | -20°C To +75°C |
---|
Mechanical Characteristics
UV Resistance | Yes |
---|
Bulk Cable Weight | 94 lbs/1000ft |
---|
Max. Pull Tension | 109 lbs |
---|
Min. Bend Radius/Minor Axis | 4.3 in |
---|
Standards
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
Suitability
Suitability - Aerial | Yes - When supported by messenger wire |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1666 Riser |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
---|
Product Notes
Notes | Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Beldfoil® provides high reliability with ease of termination. Print legend includes sequential footage marks. |
---|
History
Update and Revision | Revision Number: 0.200 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets