Indoor/Outdoor, 3-Channel SMPTE Stadium Cable, 6 Single Mode Fibers, 6 TC Conductor 18 AWG (19x30) and 6 TC Conductor 24 AWG (7x32), Beldfoil Shields, Water Blocking Tape, CPE Jacket
Specifications
Specifications
Product Overview
Suitable Applications | 3 Channel Composite Camera Cable |
---|
Multiconductor
Multiconductor Conductor and Insulation
Element | No. of Conductors | AWG | Stranding | Material | Nominal Conductor DCR | Insulation Material | Insulation Nominal Diameter |
---|
Quad 1, Quad 2, Quad 3 | 6 | 24 | 7x32 | TC - Tinned Copper | 23.3 Ohm/1000ft | PVC - Polyvinyl Chloride | 0.038 in |
Quad 1, Quad 2, Quad 3 | 6 | 18 | 19x30 | TC - Tinned Copper | 6.67 Ohm/1000ft | PVC - Polyvinyl Chloride | 0.080 in |
Multiconductor Color Chart
Description | Color |
---|
Quad 1 - 24AWG | Red |
Quad 1 - 24AWG | Gray |
Quad 1 - 18AWG | White |
Quad 1 - 18AWG | Black |
Quad 2 - 24AWG | Red/Yellow |
Quad 2 - 24AWG | Gray/Yellow |
Quad 2 - 18AWG | White/Yellow |
Quad 2 - 18AWG | Black/Yellow |
Quad 3 - 24AWG | Red/Orange |
Quad 3 - 24AWG | Gray/Orange |
Quad 3 - 18AWG | White/Orange |
Quad 3 - 18AWG | Black/Orange |
Multiconductor Inner Shield
Layer | Inner Shield Type | Inner Shield Material | Inner Shield Coverage | Drainwire AWG | Drainwire Stranding | Drainwire Material | Drainwire Position |
---|
Each Quad | Tape | Al/poly (Foil in) | 100 % | 22 | 7x30 | TC - Tinned Copper | Under Each Quad's Shield Tape |
Multiconductor UL Voltage
UL Description | UL Voltage Rating |
---|
24 AWG | 300 V RMS |
18 AWG | 300 V RMS |
Fiber
Fiber Cable Construction
Fiber Type | Fiber Count |
---|
OS2, G.657.A2 | 6 |
Fiber Color Coding | Yellow Printed |
---|
Buffer Specification
Buffer Material | Buffer Diameter |
---|
PVC - Polyvinyl Chloride | 900 µm |
Number of Active Subunits | 6 |
---|
Number of Subunit Positions | 6 |
---|
Fibers Per Subunit | 1 |
---|
Mode Field Diameter | 9.2 µm |
---|
Wavelength@Optical SM1 | 1310 nm, 1550 nm |
---|
Max. Attenuation at 1310 nm | 0.50 dB/km |
---|
Max. Attenuation at 1550 nm | 0.50 dB/km |
---|
Overall Cable
Conductor Material: | Tinned Copper |
---|
Jacket | CPE |
---|
Nominal Diameter@OuterJacket1 1_CP_OV | 0.555 in |
---|
Operating Temperature Range | -40°C to 70°C |
---|
Installation Temperature Range | -10°C to 70°C |
---|
Storage Temperature Range | -40°C to 70°C |
---|
Max. Pull Tension | 2700 N |
---|
Bulk Cable Weight | 134 lbs/1000ft |
---|
Applicable Standards & Environmental Programs
NEC/(UL) Compliance | CMR |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
CA Prop 65 (CJ for Wire and Cable) | Yes |
---|
China RoHS II (GB/T 26572-2011) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flame Test
UL Flammability | UL1666 Vertical Shaft |
---|
Plenum/Non-Plenum
Product Notes
Notes | Copper conductor quads are individually shielded with individual drain wire |
---|
History
Update and Revision | Revision Number: 0.144 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Guides
Technical Information
Data Sheets