Belden

28613A - TC VN/PVC, 37 C #18 Str BC, PVC-NYL Ins E2, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

(No reviews yet) Write a Review
SKU:
28613A
Shipping:
Calculated at Checkout
$0.00

Description

UL Type TC (1277) PVC-Nylon/PVC, 37 Conductor 18AWG (7x26) Bare Copper, PVC-NYL Insulation E2 Color Code, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Conductor(s)3718 AWG7x26BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.020 in (0.51 mm)0.087 in (2.2 mm)Black, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black, Yellow/Black, Brown/Black, Black/Red, Blue/Red, Orange/Red, Yellow/Red, Brown/Red, Black/Blue, Red/Blue, Orange/Blue, Yellow/Blue, Brown/Blue, Black/Orange, Red/Orange, Blue/Orange, Yellow/Orange, Brown/Orange, Black/Yellow, Red/Yellow, Blue/Yellow, Orange/Yellow, Brown/Yellow, Black/Brown, Red/Brown, Blue/Brown, Orange/Brown, Yellow/Brown, Black and Numbered

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.063 in (1.6 mm)0.728 in (18.5 mm)Yes
Overall Cable Diameter (Nominal)0.728 in (18.5 mm)

Electrical Characteristics

Electricals

Nom. Conductor DCRMax. Current
7.06 Ohm/1000ft5.6 Amps per Conductor at 30ºC

Voltage

UL Voltage Rating
600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C WetWet/Dry: -30°C to 90°C

Bend Radius

Stationary Min.Installation Min.
2.912 in (73.96 mm)3.64 in (92.5 mm)
Max. Pull Tension828.8 lbs (375.9 kg)
Bulk Cable Weight362 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 760, Article 336, Article 402, TC-ER, NPLF, TFFN
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.330 Revision Date: 04-14-2023
View AllClose

Additional Information

Variant_Options:
Item #|Putup Type|UPC
Variant_Options 28613A 0105000:
28613A 0105000|Reel|612825366430
View AllClose