UL Type TC (1277) PVC-Nylon/PVC, 60 Conductor 14AWG (Class B) Bare Copper, PVC-NYL Insulation E2 Color Code, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
---|
Conductor(s) | 14 | 7x22 | BC - Bare Copper | 0.071 in | 60 |
Insulation
Material | Nominal Diameter |
---|
PVC/Nylon - Polyvinyl Chloride + Nylon | 0.112 in |
Color Chart
Number | Color |
---|
1 | Black |
2 | Red |
3 | Blue |
4 | Orange |
5 | Yellow |
6 | Brown |
7 | Red/Black |
8 | Blue/Black |
9 | Orange/Black |
10 | Yellow/Black |
11 | Brown/Black |
12 | Black/Red |
13 | Blue/Red |
14 | Orange/Red |
15 | Yellow/Red |
16 | Brown/Red |
17 | Black/Blue |
18 | Red/Blue |
19 | Orange/Blue |
20 | Yellow/Blue |
21 | Brown/Blue |
22 | Black/Orange |
23 | Red/Orange |
24 | Blue/Orange |
25 | Yellow/Orange |
26 | Brown/Orange |
27 | Black/Yellow |
28 | Red/Yellow |
29 | Blue/Yellow |
30 | Orange/Yellow |
31 | Brown/Yellow |
32 | Black/Brown |
33 | Red/Brown |
34 | Blue/Brown |
35 | Orange/Brown |
36 | Yellow/Brown |
37-60 | Repeats of 1-24 respectively |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 1.192 in | 0.083 in |
Construction and Dimensions
Cabling
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
2.52 Ohm/1000ft |
Current
Max. Recommended Current [A] |
---|
8.8 Amps per Conductor at 30ºC |
Voltage
UL Description | UL Voltage Rating | Voltage Rating [V] |
---|
TC-ER | 600 V RMS (Type TC) | 600 V RMS (Type TC) |
Temperature Range
UL Temp Rating | 90°C Dry, 90°C Wet |
---|
Operating Temperature Range | -25°C To +90°C |
---|
Wet Temp Range | -30°C To +90 °C |
---|
Dry Temp Range | -30°C To +90 °C |
---|
Mechanical Characteristics
Bulk Cable Weight | 1324 lbs/1000ft |
---|
Min Bend Radius (Overall) | 12 in |
---|
Min. Bend Radius/Minor Axis | 5.96 in |
---|
Standards
NEC Articles | Article 336 |
---|
NEC/(UL) Compliance | TC-ER, THHN, THWN |
---|
IEEE Compliance | 1202 |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
CA Prop 65 | Yes |
---|
Suitability
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEEE Flammability | 1202 |
---|
UL voltage rating | 600 V RMS (Type TC) |
---|
History
Update and Revision | Revision Number: 0.51 Revision Date: 04-14-2023 |
---|
Documentation
Catalogs
Tools
Data Sheets