Belden

29520C - VFD, 3C #16 Str BC XLPE Ins + #14 Symm. Seg. Gnd (3 of #18) Str BC, CTS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

(No reviews yet) Write a Review
SKU:
29520C
Shipping:
Calculated at Checkout
$0.00

Description

Belden Basics VFD, 3 Conductor 16AWG (7x24) Bare Copper XLPE Insulation M4 Color Code + 14AWG Symmetrical Segmented Ground (3 of 18AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)316 AWG7x24BC - Bare Copper
Ground Wire318 AWG7x26BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.031 in (0.79 mm)0.123 in (3.12 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.060 in (1.5 mm)0.397 in (10.1 mm)Yes
Overall Cable Diameter (Nominal)0.397 in (10.1 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)3.91 Ohm/1000ft37 pF/ft (120 pF/m)67 pF/ft (220 pF/m)50 Ohm55%18 Amps per Conductor at 30ºC
7.06 Ohm/1000ft (23.2 Ohm/km)14 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating
600 V (TC-ER)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
4.8 in (120 mm)4.8 in (120 mm)
Max. Pull Tension130 lbs (59 kg)
Bulk Cable Weight116 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.565 Revision Date: 01-20-2023