Belden Basics VFD, 3 Conductor 14AWG (7x22) Bare Copper XLPE Insulation M4 Color Code + 14AWG Symmetrical Segmented Ground (3 of 18AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant
Specifications
Specifications
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | Notes |
|---|
| Conductor(s) | 3 | 14 AWG | 7x22 | BC - Bare Copper | |
| Ground Wire | 3 | 18 AWG | 7x26 | BC - Bare Copper | Segmented Grounds |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.030 in (0.76 mm) | 0.131 in (3.33 mm) | ICEA Chart M4 |
| Ground Wire | No Insulation | | | |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Helical Tape | Bare Copper (BC) | 100% |
| Helical Tape | Bare Copper (BC) | 100% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.060 in (1.5 mm) | 0.425 in (10.8 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.425 in (10.8 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|
| Conductor(s) | 2.282 Ohm/1000ft | 23 pF/ft (75 pF/m) | 42 pF/ft (140 pF/m) | 80 Ohm | 55% | 25 Amps per Conductor at 30ºC |
| 7.06 Ohm/1000ft (23.2 Ohm/km) | | | | | 25 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 600 / 1000 V (TC-ER) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 5.1 in (130 mm) | 5.1 in (130 mm) |
| Max. Pull Tension | 186 lbs (84.4 kg) |
|---|
| Bulk Cable Weight | 134 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | UL 1685 UL Loading, IEEE 1202 FT4 |
|---|
| NEC / UL Compliance | Article 336, TC-ER, XHHW-2 |
|---|
| ICEA Compliance | S-95-658 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.571 Revision Date: 04-14-2023 |
|---|