Belden

29531C - VFD, 3C #3/0 Str BC XLPE Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

(No reviews yet) Write a Review
SKU:
29531C
Shipping:
Calculated at Checkout
$0.00

Description

Belden Basics VFD, 3 Conductor 3/0AWG (19x11) Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)33/0 AWG19x11BC - Bare Copper
Ground38 AWG7x16BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.060 in (1.5 mm)0.575 in (14.6 mm)ICEA Chart M4
GroundNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.083 in (2.1 mm)1.417 in (35.99 mm)Yes
Overall Cable Diameter (Nominal)1.417 in (35.99 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.065 Ohm/1000ft33 pF/ft (110 pF/m)60 pF/ft (200 pF/m)56 Ohm55%225 Amps per Conductor at 30ºC (per NEC)
0.68 Ohm/1000ft (2.2 Ohm/km)55 Amps per Conductor at 25ºC

Voltage

UL Voltage RatingVoltage Rating
1000 V (TC-ER)1000 V (CSA AWM I/II A/B)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
17.0 in (432 mm)17.0 in (432 mm)
Max. Pull Tension6716 lbs (3046 kg)
Bulk Cable Weight2144 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
AWM ComplianceAWM I/II A/B
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.541 Revision Date: 04-14-2023

Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 29531C 0101000:
29531C 0101000|Black|Reel|1,000 ft|612825138204
Variant_Options 29531C 0102000:
29531C 0102000|Black|Reel|2,000 ft|612825138211
View AllClose