Belden

29533 - VFD, 3C 250MCM Str BC XLPE Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA 22.2 No. 230 TC

(No reviews yet) Write a Review
SKU:
29533
Shipping:
Calculated at Checkout
$0.00

Description

Belden Basics VFD, 3 Conductor 250MCM (37x.0822") Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA 22.2 No. 230 TC SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)3250 MCM37x0.0822 in.BC - Bare Copper
Ground Wire38 AWG7x16BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.105 in (2.67 mm)0.768 in (19.5 mm)ICEA Method 4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.110 in (2.79 mm)1.912 in (48.56 mm)Yes
Overall Cable Diameter (Nominal)1.912 in (48.56 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.041 Ohm/1000ft30 pF/ft (98 pF/m)54 pF/ft (180 pF/m)62 Ohm55%290 Amps per Conductor at 30ºC (per NEC)
0.68 Ohm/1000ft (2.2 Ohm/km)55 Amps per Conductor at 25ºC

Voltage

UL Voltage RatingVoltage Rating
2000 V (TC, UL44)1000 V (CSA TC)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
22.9 in (582 mm)22.9 in (582 mm)
Max. Pull Tension1743 lbs (790.6 kg)
Bulk Cable Weight3730 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
CEC / C(UL) ComplianceCSA TC
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.540 Revision Date: 04-14-2023

Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 29533 0102000:
29533 0102000|Black|Reel||612825353140
Variant_Options 29533 0101500:
29533 0101500|Black|Reel|1,500 m|612825138334
Variant_Options 29533 0102300:
29533 0102300|Black|Reel|2,300 ft|612825138341
View AllClose