Belden

29557C - VFD, 3C #1 Str BC XLPE Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 1000V CSA TC C22.2 #230 C22.2 #38

(No reviews yet) Write a Review
SKU:
29557C
Shipping:
Calculated at Checkout
$0.00

Description

Belden Basics CSA VFD, 3 Conductor 1AWG (19x14) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 1000V CSA TC C22.2 #230 C22.2 #38 SUN RES DIR BUR Oil Resistance

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Specific ratings for applications in Canada

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)31 AWG19x14BC - Bare Copper
Ground310 AWG7x18BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.083 in (2.1 mm)Black and Numbered
GroundNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.093 in (2.4 mm)1.269 in (32.23 mm)Yes
Overall Cable Diameter (Nominal)1.269 in (32.23 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.131 Ohm/1000ft (0.430 Ohm/km)21 pF/ft (69 pF/m)38 pF/ft (120 pF/m)90 Ohm55%145 Amps per Conductor at 30ºC (per NEC)

Voltage

UL Voltage Rating
1000 V (CSA TC)

Mechanical Characteristics

Temperature

Operating
-40°C To 90°C

Bend Radius

Stationary Min.Installation Min.
15.2 in (386 mm)15.2 in (386 mm)
Max. Pull Tension3222 lbs (1461 kg)
Bulk Cable Weight1307 lbs/1000ft (1945 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to Fire1202, 383 Vertical Tray Flame Test (70,000 BTU)
CEC / C(UL) ComplianceTC, RW90, C22.2 #230, #38
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.350 Revision Date: 12-20-2022

Documentation

Data Sheets

View AllClose