Belden Basics CSA VFD, 3 Conductor 3/0AWG (19x11) Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 1000V CSA TC C22.2 #230 C22.2 #38 SUN RES DIR BUR Oil Resistance
Specifications
Specifications
Product Overview
Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; Specific ratings for applications in Canada |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material | Notes |
---|
Conductor(s) | 3 | 3/0 AWG | 19x10 | BC - Bare Copper | |
Ground Wire | 3 | 8 AWG | 7x16 | BC - Bare Copper | Segmented Grounds |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.080 in (2.0 mm) | 0.622 in (15.8 mm) | ICEA Chart M4 |
Ground Wire | No Insulation | | | |
Outer Shield
Shield Type | Material | Coverage |
---|
Tape | Polypropylene Foam | 100% |
Helical Tape | Bare Copper (BC) | 100% |
Helical Tape | Bare Copper (BC) | 100% |
Table Notes | Separator-Polypropylene Tape |
---|
Outer Jacket
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.093 in (2.4 mm) | 1.553 in (39.45 mm) | Yes |
Overall Cable Diameter (Nominal) | 1.553 in (39.45 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
Conductor(s) | 0.065 Ohm/1000ft | 33 pF/ft (110 pF/m) | 60 pF/ft (200 pF/m) | 56 Ohm | 55% | 225 Amps per Conductor at 30ºC |
| 0.68 Ohm/1000ft (2.2 Ohm/km) | | | | | 55 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating | Voltage Rating |
---|
1000 V (CSA TC) | 1000 V (CSA TC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
18.7 in (475 mm) | 18.7 in (475 mm) |
Max. Pull Tension | 6716 lbs (3046 kg) |
---|
Bulk Cable Weight | 2273 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | UL 1685 UL Loading |
---|
CEC / C(UL) Compliance | CSA TC |
---|
ICEA Compliance | S-95-658 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.377 Revision Date: 01-20-2023 |
---|