Belden Basics CSA VFD, 3 Conductor 4/0AWG (19x10) Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 1000V CSA TC C22.2 #230 C22.2 #38 SUN RES DIR BUR Oil Resistance
Specifications
Specifications
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; Specific ratings for applications in Canada |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | Notes |
|---|
| Conductor(s) | 3 | 4/0 AWG | 19x10 | BC - Bare Copper | |
| Ground | 3 | 8 AWG | 7x16 | BC - Bare Copper | Segmented Grounds |
Insulation
| Element | Material | Nom. Thickness | Color Code |
|---|
| Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.085 in (2.2 mm) | Black and Numbered |
| Ground | No Insulation | | |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Helical Tape | Bare Copper (BC) | 100% |
| Helical Tape | Bare Copper (BC) | 100% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.093 in (2.4 mm) | 1.681 in (42.70 mm) | Yes |
| Overall Cable Diameter (Nominal) | 1.681 in (42.70 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|
| Conductor(s) | 0.052 Ohm/1000ft (0.17 Ohm/km) | 33 pF/ft (110 pF/m) | 60 pF/ft (200 pF/m) | 56 Ohm | 55% | 260 Amps per Conductor at 30ºC |
Voltage
| UL Voltage Rating |
|---|
| 1000 V (CSA TC) |
Mechanical Characteristics
Temperature
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 20.2 in (513 mm) | 20.2 in (513 mm) |
| Max. Pull Tension | 7814 lbs (3544 kg) |
|---|
| Bulk Cable Weight | 2767 lbs/1000ft (4118 kg/km) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
|---|
| CEC / C(UL) Compliance | TC, RW90, C22.2 #230, #38 |
|---|
| ICEA Compliance | S-95-658 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.342 Revision Date: 12-20-2022 |
|---|