Description

Belden Basics VFD, 3 Conductor 2AWG (7x10) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)32 AWG7x10BC - Bare Copper
Ground Wire310 AWG7x18BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPO - Crosslink Polyolefin0.073 in (1.9 mm)0.428 in (10.9 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.083 in (2.1 mm)1.100 in (27.94 mm)Yes
Overall Cable Diameter (Nominal)1.100 in (27.94 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.14 Ohm/1000ft21 pF/ft (69 pF/m)38 pF/ft (120 pF/m)90 Ohm55%130 Amps per Conductor at 30ºC
1.08 Ohm/1000ft (3.54 Ohm/km)40 Amps per Conductor at 30ºC

Voltage

UL Voltage Rating
2000 V (TC), 1000 V (CSA AWM I/II A/B)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
13.2 in (335 mm)13.2 in (335 mm)
Max. Pull Tension2821 lbs (1280 kg)
Bulk Cable Weight1032 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
AWM ComplianceAWM I/II A/B
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.83 Revision Date: 04-14-2023

Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Putup Type|UPC
Variant_Options 29727C 0101000:
29727C 0101000|Reel|612825445708
Variant_Options 29727C 0102500:
29727C 0102500|Reel|612825445715
Variant_Options 29727C 0105000:
29727C 0105000|Reel|612825445722
View AllClose