Belden

29731C - VFD, 3C #3/0 Str BC XLPE Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

(No reviews yet) Write a Review
SKU:
29731C
Shipping:
Calculated at Checkout
$0.00

Description

Belden Basics VFD, 3 Conductor 3/0AWG (19x11) Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterialNotes
Conductor(s)33/0 AWG19x11BC - Bare Copper
Ground38 AWG7x16BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.094 in (2.4 mm)0.643 in (16.3 mm)Black and Numbered
GroundNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.083 in (2.1 mm)1.564 in (39.73 mm)Yes
Overall Cable Diameter (Nominal)1.564 in (39.73 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.066 Ohm/1000ft (0.22 Ohm/km)23 pF/ft (75 pF/m)42 pF/ft (140 pF/m)80 Ohm55%225 Amps per Conductor at 30ºC

Voltage

UL Voltage Rating
2000 V (TC), 1000 V (CSA AWM I/II A/B)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-40°C To +90°C

Bend Radius

Stationary Min.Installation Min.
18.8 in (478 mm)18.8 in (478 mm)
Max. Pull Tension6332 lbs (2872 kg)
Bulk Cable Weight2227 lbs/1000ft (3314 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 UL Loading, 1202, 383 Vertical Tray Flame Test (70,000 BTU)
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
AWM ComplianceI/II A/B
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.67 Revision Date: 04-14-2023

Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Putup Type|UPC
Variant_Options 29731C 0101000:
29731C 0101000|Reel|612825445593
Variant_Options 29731C 0102500:
29731C 0102500|Reel|612825445609
View AllClose