Belden

3046A - Inst, 4 Tri #16+22 Str BC, PVC Ins E1, OS, Blk PVC Jkt, 300V PLTC ITC CMG

(No reviews yet) Write a Review
SKU:
3046A
Shipping:
Calculated at Checkout
$0.00

Description

UL Instrumentation, 4 Triad 16+22AWG (7x24+7x30) Bare Copper, PVC Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES DIR BUR

Specifications

Specifications

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …),RTD, control circuits, distributed control system (DCS),programmable logic controller (PLC),  Solenoids, Valves, actuators, positioners

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Triad(s)416 AWG7x24BC - Bare Copper
Comm Wire(s)122 AWG7x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Triad(s)PVC - Polyvinyl Chloride0.015 in (0.38 mm)0.090 in (2.3 mm)Black, White, Red and Numbered
Comm Wire(s)PVC - Polyvinyl Chloride0.015 in (0.38 mm)0.060 in (1.5 mm)Orange

Inner Shield

ElementShield Type
Comm Wire(s)No Shield

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%16 AWG (7x24) TC

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.053 in (1.3 mm)0.528 in (13.4 mm)Yes
Overall Cable Diameter (Nominal)0.528 in (13.4 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCR
Pair(s)4.2 Ohm/1000ft (14 Ohm/km)
Comm Wire(s)14.7 Ohm/1000ft (48.2 Ohm/km)

Voltage

UL Voltage Rating
300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)

Mechanical Characteristics

Temperature

UL TemperatureOperating
105°C-30°C to +105°C

Bend Radius

Stationary Min.Installation Min.
5.3 in (130 mm)5.3 in (130 mm)
Max. Pull Tension428 lbs (194 kg)
Bulk Cable Weight188 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 (FT4 Loading), FT4, 1202
NEC / UL ComplianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM ComplianceAWM 2464
CEC / C(UL) ComplianceCMG
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.58 Revision Date: 04-14-2023
View AllClose