Belden
3072F - Blue Hose®, 1 Pr #18 Str TC, PP Ins, OS+TC Brd, PVC Jkt, 600V TC, PLTC
- SKU:
- 3072F
- Shipping:
- Calculated at Checkout
Description
Blue Hose® for Data Highway Plus, 1 Pair 18AWG (7x26) Tinned Copper, PP Insulation, Overall Beldfoil®+Tinned Copper Braid(55%) Shield, PVC Outer Jacket, 600V TC, PLTC
Specifications
Specifications
Product Overview
Suitable Applications | harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 18 AWG | 7x26 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|---|---|
Pair(s) | PP - Polypropylene | 0.025 in (0.64 mm) | 0.096 in (2.4 mm) | Blue & White | Flame Retardant |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
Braid | Tinned Copper (TC) | 55% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.053 in (1.3 mm) | 0.324 in (8.23 mm) |
Table Notes | Jacket OD +/- 0.006 |
---|---|
Overall Cable Diameter (Nominal) | 0.324 in (8.23 mm) |
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|
Pair(s) | 7.2 Ohm/1000ft | 19.5 pF/ft (64.0 pF/m) | 78 Ohm | 65% | 5.2 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR | 2.1 Ohm/1000ft (6.9 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.52 dB/100ft |
10 | 1.98 dB/100ft | |
50 | 3.78 dB/100ft | |
100 | 5.35 dB/100ft | |
200 | 7.57 dB/100ft | |
400 | 10.7 dB/100ft |
Voltage
UL Voltage Rating | Voltage Rating |
---|---|
600 V (TC), 300 V (CMG, PLTC) | 150 V (ITC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
75°C | -40°C to +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
3 in (76 mm) | 4 in (100 mm) |
Max. Pull Tension | 85 lbs (39 kg) |
---|---|
Bulk Cable Weight | 64 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor, Sunlight Resistance |
---|---|
Flammability / Reaction to Fire | UL 1685 FT4 Loading, FT4, IEEE 1202 |
CPR Compliance | CPR Euroclass: Eca |
NEC / UL Compliance | Article 336, Article 725, Article 727, Article 800, TC |
CEC / C(UL) Compliance | CMG |
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance | UKCA Mark |
APAC Compliance | China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s) | P-MSHA-SC-182/7 |
Product Notes
Notes | For CPE jacketed version, order Part No. YM45044. |
---|
History
Update and Revision | Revision Number: 0.537 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Reference Manuals
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC |
Variant_Options 3072F C55500: |
3072F C55500|Blue, Cairo|Reel|500 ft|612825140092 |
Variant_Options 3072F C551000: |
3072F C551000|Blue, Cairo|Reel|1,000 ft|612825140054 |
Variant_Options 3072F C555000: |
3072F C555000|Blue, Cairo|Reel|5,000 ft|612825140108 |
Variant_Options 3072F C5510000: |
3072F C5510000|Blue, Cairo|Reel|10,000 ft|612825140061 |