Twinax 100Ω, 1 Pair 18 AWG (7x26) Tinned Copper, PP Insulation, Overall Beldfoil®+Tinned Copper Braid(55%) Shield, PVC Outer Jacket, TC, PLTC, ITC, CMG
Specifications
Specifications
Product Overview
Suitable Applications | Harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Nom. Diameter | Material |
---|
Pair(s) | 1 | 18 AWG | 7x26 | 0.046 in | TC - Tinned Copper |
Insulation
Element | Material | Nom. Insulation Diameter | Color Code | Notes |
---|
Pair(s) | PP - Polypropylene | 0.128 in (3.25 mm) | White & Blue | Flame Retardant |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage | Notes |
---|
1 | Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Foil Out |
2 | Braid | Tinned Copper (TC) | | 55% | |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.388 in (9.86 mm) |
Overall Cable Diameter (Nominal) | 0.388 in (9.86 mm) |
---|
Electrical Characteristics
Attenuation
Frequency | Nom. Attenuation |
---|
2 MHz | 0.41 dB/100ft |
10 MHz | 1.33 dB/100ft |
50 MHz | 2.97 dB/100ft |
100 MHz | 4.20 dB/100ft |
200 MHz | 5.95 dB/100ft |
400 MHz | 7.52 dB/100ft |
Electricals
Element | Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Cond (Mutual) | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
Pair(s) | 6.9 Ohm/1000ft | 2.9 Ohm/1000ft (9.5 Ohm/km) | 15.3 pF/ft (50.2 pF/m) | 100 Ohm | 65% |
Voltage
UL Voltage Rating |
---|
600 V (TC), 300 V (CMG, PLTC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C Dry, PLTC 75°C Dry/Wet | -40°C to +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
3.2 in (81 mm) | 2.4 in (61 mm) |
Max. Pull Tension | 90 lbs (41 kg) |
---|
Bulk Cable Weight | 77 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, UV Resistance, Aerial - When supported by messenger wire |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | UL1685 UL Loading, FT1FT4 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 336, Article 725, Article 727, Article 800, CMG, ITC, PLTC, TC |
---|
CEC / C(UL) Compliance | CMG |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Cable contains rod fillers for better electrical performance. CPE Jacket Optional. |
---|
History
Update and Revision | Revision Number: 0.482 Revision Date: 05-25-2023 |
---|
Documentation
Product Bulletins
Catalogs
Guides
Line Cards
Compliance Documentation
Data Sheets