Fieldbus, 1 Pair AWG 22 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil(s) or Copper Tape(s) shielding, LSZH / FRNC jacket , 300V SWA
Specifications
Specifications
Product Overview
| Suitable Applications | Instrumentation and computer cable; For data transmission applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 22 | 7x30 | TC - Tinned Copper | 1 |
| Conductor Count | 2 |
|---|
| Total Number of Pairs | 1 |
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 1.5 mm | 0.05 mm | 0.375 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | White & Black |
Inner Shield
| Type | Material | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | TC - Tinned Copper | AWG22/7 |
Inner Jacket
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Orange or Blue | 7.5 mm | 2.15 mm |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 13 mm | 1.85 mm |
Construction and Dimensions
Armor
| Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
|---|
| Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | Max. Outer Shield DCR |
|---|
| 52.5 Ohm/km | 41.5 Ohm/km |
Capacitance
| Max. Capacitance Conductor to Conductor | Max. Capacitance Conductor to Shield |
|---|
| 85 pF/m | 160 pF/m |
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance | Nominal Characteristic Tolerance |
|---|
| 0.03125 MHz | 100 Ohm | 5 Ohm |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 66% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|
| 0.01 MHz | 0.61 dB/100m |
| 0.039 MHz | 0.67 dB/100m |
| 0.1 MHz | 0.91 dB/100m |
| 0.5 MHz | 3.5 dB/100m |
| 1 MHz | 5.1 dB/100m |
Voltage
Temperature Range
| Installation Temperature Range | -15°C To +80°C |
|---|
| Storage Temperature Range | -45°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | ASTMD741 |
|---|
| Max. Pull Tension | 50 N |
|---|
| Min. Bend Radius During Installation | 140 mm |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Outdoor |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|