Belden

3083A - DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, CMG PLTC

(No reviews yet) Write a Review
SKU:
3083A
Shipping:
Calculated at Checkout
$0.00

Description

DeviceBus® for ODVA DeviceNet™, 2 Pair 15+18AWG (19x27+19x30) Tinned Copper, PVC+Foam PE Insulation, Individual Beldfoil® & OA Tinned Copper Braid(65%) Shield, CPE Outer Jacket, CMG PLTC

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Power Pair(s)115 AWG19x27TC - Tinned Copper
Data Pair(s)118 AWG19x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor CodeNotes
Power Pair(s)PVC - Polyvinyl Chloride0.021 in (0.53 mm)0.109 in (2.77 mm)Red & Black
Data Pair(s)PE - Polyethylene (Foam)0.053 in (1.3 mm)0.150 in (3.81 mm)Blue & WhiteHDPE

Inner Shield

ElementShield TypeMaterialCoverage
Power Pair(s)TapeBi-Laminate (Alum+Poly)100%
Data Pair(s)TapeBi-Laminate (Alum+Poly)100%

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
BraidTinned Copper (TC)65%18 AWG (19x30) TC

Outer Jacket

MaterialNom. ThicknessNom. Diameter
CPE - Chlorinated Polyethylene0.058 in (1.5 mm)0.476 in (12.1 mm)
Table NotesJacket OD +/- 0.015
Overall Cable Diameter (Nominal)0.476 in (12.1 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Inner Shield DCRNom. Capacitance Cond-to-CondNom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Power Pair(s)3.58 Ohm/1000ft5.75 Ohm/1000ft (18.9 Ohm/km)24 Amps per Conductor at 30ºC
Data Pair(s)7.2 Ohm/1000ft (24 Ohm/km)3.58 Ohm/1000ft (11.7 Ohm/km)12 pF/ft (39 pF/m)120 Ohm75%14 Amps per Conductor at 30ºC
Nom. Outer Shield DCR7.29 Ohm/1000ft (23.9 Ohm/km)

High Frequency

ElementFrequency [MHz]Max. Insertion Loss (Attenuation)Max./Min. Input Impedance (unFitted) [Ohm]
Data Pair(s)0.1250.13 dB/100ft120
0.50.25 dB/100ft
10.36 dB/100ft

Voltage

UL Voltage Rating
300 V (CMG, PLTC-ER)

Mechanical Characteristics

Temperature

UL TemperatureOperating
105°C-20°C to +105°C

Bend Radius

Stationary Min.Installation Min.
5.712 in (145.1 mm)5.712 in (145.1 mm)
Max. Pull Tension192.6 lbs (87.36 kg)
Bulk Cable Weight127 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL 1685 FT4 Loading, IEEE 1202 FT4
CPR ComplianceCPR Euroclass: Fca
NEC / UL ComplianceArticle 725, Article 800, CMG, PLTC
CEC / C(UL) ComplianceCMG
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)ODVA Class 2 Thick

Product Notes

NotesThick. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. Jacket printed ""1PR16"" instead of ""1PR15"" due to UL requirements for CMG Listing.

History

Update and RevisionRevision Number: 0.525 Revision Date: 04-14-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 3083A 5601000:
3083A 5601000|Yellow, Bright|Reel|1,000 ft|612825140856
Variant_Options 3083A 5602000:
3083A 5602000|Yellow, Bright|Reel|2,000 ft|612825140863
View AllClose