UL Instrumentation, 1 Triad 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR
Specifications
Specifications
Product Overview
| Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …),RTD, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, actuators, positioners |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Triad(s) | 1 | 18 AWG | 7x26 | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Triad(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.022 in (0.56 mm) | 0.088 in (2.2 mm) | Black, White, Red |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.047 in (1.2 mm) | 0.290 in (7.37 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.290 in (7.37 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Max. Current |
|---|
| Triad(s) | 7.06 Ohm/1000ft | 47.3 pF/ft (155 pF/m) | 84.2 pF/ft (276 pF/m) | 5 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 600 V (TC-ER), 150 V (NPLF) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 90°C Dry, 90°C Wet | -30°C to +90°C Dry, 75°C wet |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 3.5 in (89 mm) | 3.5 in (89 mm) |
| Max. Pull Tension | 80 lbs (36 kg) |
|---|
| Bulk Cable Weight | 47 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
|---|
| Flammability / Reaction to Fire | UL 1685 UL Loading, IEEE 1202, FT4 |
|---|
| NEC / UL Compliance | Article 336, Article 760, NPLF, TC-ER |
|---|
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.539 Revision Date: 04-14-2023 |
|---|
Documentation
Catalogs
Compliance Documentation
Data Sheets