Coax RG-6 20 AWG (105x40) Bare Copper, Foam PE Insulation, Overall Duobond® II+Aluminum Braid(60%)+Duofoil®+Aluminum Braid(40%) Shield, PVC Outer Jacket, High Flex, CMR
Specifications
Specifications
Product Overview
Suitable Applications | Harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
---|
Construction Details
Conductor
Size | Stranding | Nom. Diameter | Material |
---|
20 AWG | 105x40 | 0.040 in | BC - Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PE - Polyethylene (Foam) | 0.183 in (4.65 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
2 | Braid | Aluminum | | 60% |
3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
4 | Braid | Aluminum | | 40% |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.303 in (7.70 mm) |
Overall Cable Diameter (Nominal) | 0.303 in (7.70 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Structural Return Loss |
---|
5 - 400 MHz | 23 dB |
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.36 dB/100ft |
2 MHz | 0.47 dB/100ft |
5 MHz | 0.8 dB/100ft |
10 MHz | 1.2 dB/100ft |
20 MHz | 2.0 dB/100ft |
50 MHz | 3.2 dB/100ft |
100 MHz | 4.6 dB/100ft |
200 MHz | 6.5 dB/100ft |
300 MHz | 8 dB/100ft |
400 MHz | 9.3 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
10.5 Ohm/1000ft | 2.6 Ohm/1000ft (8.5 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 82% |
Voltage
UL Voltage Rating |
---|
300 V (CMR, CMG) |
Electrical Characteristics Notes | IEEE 802.4 MAP/IEEE 802.7 Mini-Map |
---|
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C | -40°C to +75°C |
Bend Radius
Installation Min. |
---|
3 in (76 mm) |
Max. Pull Tension | 35 lbs (16 kg) |
---|
Bulk Cable Weight | 29 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor - Riser, Indoor, Aerial - When supported by messenger wire |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | UL 1666 Riser |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | CMR, CL2R |
---|
CEC / C(UL) Compliance | CMG |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Flex Life: 1.5 Million cycles @ 6.0"" minimum bend radius. For Rockwell authorized Flexible ControlNet order YR28890 (Tinned Copper Braid Version). |
---|
History
Update and Revision | Revision Number: 0.507 Revision Date: 05-25-2023 |
---|
Documentation
Catalogs
Technical Resources
Compliance Documentation
Data Sheets