Belden

3092T - ControlBus™, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, LSZH Jkt, CMG

(No reviews yet) Write a Review
SKU:
3092T
Shipping:
Calculated at Checkout
$0.00

Description

ControlBus™, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, PO Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, LSZH Outer Jacket, CMG

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNominal DiameterNo. of Coax
18SolidBCCS - Bare Copper Covered Steel0.040 in1
Conductor Count1

Insulation

MaterialNominal Diameter
PE - Polyethylene (Foam)0.180 in

Outer Shield

TypeLayerMaterialMaterial Trade NameCoverage [%]
Tape1Tri-Laminate (Alum+Poly+Alum)Duobond® II100%
Braid2Aluminum60%
Tape3Tri-Laminate (Alum+Poly+Alum)Duofoil®100%
Braid4Aluminum60%

Outer Jacket

MaterialNominal Diameter
PE - Polyethylene0.3 in
Table NotesFlame Retardant

Electrical Characteristics

Conductor DCR

Nominal Conductor DCROuter Conductor DCR
28 Ohm/1000ft3.6 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Shield
16.2 pF/ft

Inductance

Nominal Inductance
0.097 µH/ft

Impedance

Nominal Characteristic Impedance
75 Ohm

Return Loss

Frequency [MHz]Min. Structural Return Loss (SRL)
5-50 MHz23 dB

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss
1 MHz0.35 dB/100ft
2 MHz0.38 dB/100ft
5 MHz0.45 dB/100ft
10 MHz0.59 dB/100ft
20 MHz0.86 dB/100ft
50 MHz1.37 dB/100ft
100 MHz1.97 dB/100ft
200 MHz2.82 dB/100ft
300 MHz3.48 dB/100ft
400 MHz4.04 dB/100ft

Delay

Nominal DelayNominal Velocity of Propagation (VP) [%]
1.25 ns/ft83%

Voltage

UL Voltage Rating
300 V RMS

Temperature Range

UL Temp Rating75°C
Operating Temperature Range-20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight35 lbs/1000ft
Max. Pull Tension162 lbs
Min. Bend Radius/Minor Axis3.0 in

Standards

NEC/(UL) ComplianceCL2, CMG
CEC/C(UL) ComplianceCMG
RG Type6

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes

Flammability, LS0H, Toxicity Testing

IEC FlammabilityIEC 60332-3-22
IEEE Flammability1202
UL voltage rating300 V RMS

History

Update and RevisionRevision Number: 0.329 Revision Date: 05-05-2023

Documentation

Catalogs

Technical Resources

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|UPC
Variant_Options 3092T 0105000:
3092T 0105000|Black|612825141433
View AllClose