Coax RG-6 18 AWG (Solid) Bare Copper Covered Steel, Foam FEP Insulation, Overall Duobond® II+ Aluminum Braid(60%)+Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP High Temp 150C
Specifications
Specifications
Product Overview
Suitable Applications | Harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
---|
Construction Details
Conductor
Size | Stranding | Nom. Diameter | Material |
---|
18 AWG | Solid | 0.040 in | BCCS - Bare Copper Covered Steel |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
FEP - Fluorinated Ethylene Propylene (Foam) | 0.170 in (4.32 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
2 | Braid | Aluminum | | 60% |
3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
4 | Braid | Aluminum | | 40% |
Outer Jacket
Material | Nom. Diameter |
---|
PVDF - Polyvinylidene Fluoride | 0.274 in (6.96 mm) |
Overall Cable Diameter (Nominal) | 0.274 in (6.96 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Structural Return Loss |
---|
5 - 50 MHz | 23 dB |
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.34 dB/100ft |
2 MHz | 0.37 dB/100ft |
5 MHz | 0.44 dB/100ft |
10 MHz | 0.58 dB/100ft |
20 MHz | 0.85 dB/100ft |
50 MHz | 1.39 dB/100ft |
100 MHz | 1.99 dB/100ft |
200 MHz | 2.92 dB/100ft |
300 MHz | 3.68 dB/100ft |
400 MHz | 4.38 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
28 Ohm/1000ft | 2.6 Ohm/1000ft (8.5 Ohm/km) | 16.5 pF/ft (54.1 pF/m) | 75 Ohm | 82% |
Voltage
UL Voltage Rating |
---|
300 V (CMP) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
150°C | -20°C to +150°C |
Bend Radius
Installation Min. |
---|
2.75 in (69.9 mm) |
Max. Pull Tension | 104 lbs (47.2 kg) |
---|
Bulk Cable Weight | 36 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor - Plenum, Indoor, Outdoor, Aerial - When supported by messenger wire, Burial |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | NFPA 262 |
---|
NEC / UL Compliance | CMP |
---|
CEC / C(UL) Compliance | CMP |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Non-Plenum Number | 3092A |
---|
Product Notes
Notes | Blue available as standard in 1000-ft put-up only. Suitable for Outdoor and Direct Burial applications. |
---|
History
Update and Revision | Revision Number: 0.498 Revision Date: 05-25-2023 |
---|
Documentation
Catalogs
Technical Resources
Compliance Documentation
Data Sheets