Coax RG-11 14AWG (Solid) Bare Copper Covered Steel, Foam PE Insulation, Overall Duobond® II+ Aluminum Braid(60%)+Duofoil®+Aluminum Braid(40%) Shield, PVC Outer Jacket, CMR
Specifications
Specifications
Product Overview
| Suitable Applications | Harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications | 
|---|
Construction Details
Conductor
| Size | Stranding | Nom. Diameter | Material | 
|---|
| 14 AWG | Solid | 0.064 in | BCCS - Bare Copper Covered Steel | 
Insulation
| Material | Nom. Insulation Diameter | Color Code | Notes | 
|---|
| PE - Polyethylene (Foam) | 0.280 in (7.11 mm) | White | Gas Injected | 
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage | 
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% | 
| 2 | Braid | Aluminum |  | 60% | 
| 3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% | 
| 4 | Braid | Aluminum |  | 40% | 
Outer Jacket
| Material | Nom. Diameter | 
|---|
| PVC - Polyvinyl Chloride | 0.407 in (10.3 mm) | 
| Overall Cable Diameter (Nominal) | 0.407 in (10.3 mm) | 
|---|
Electrical Characteristics
Return Loss
| Frequency | Min. Structural Return Loss | 
|---|
| 5 - 400 MHz | 20 dB | 
Attenuation
| Frequency | Nom. Attenuation | 
|---|
| 1 MHz | 0.16 dB/100ft | 
| 2 MHz | 0.18 dB/100ft | 
| 5 MHz | 0.26 dB/100ft | 
| 10 MHz | 0.38 dB/100ft | 
| 20 MHz | 0.55 dB/100ft | 
| 50 MHz | 0.83 dB/100ft | 
| 100 MHz | 1.17 dB/100ft | 
| 200 MHz | 1.60 dB/100ft | 
| 300 MHz | 1.99 dB/100ft | 
| 400 MHz | 2.30 dB/100ft | 
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance 
        Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. | 
|---|
| 11.5 Ohm/1000ft | 1.8 Ohm/1000ft (5.9 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 83% | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CMR, CMG) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 75°C | -30°C to 75°C | 
Bend Radius
| Installation Min. | 
|---|
| 4 in (100 mm) | 
| Max. Pull Tension | 234 lbs (106 kg) | 
|---|
| Bulk Cable Weight | 60 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire | 
|---|
| Sustainability | CA Prop 65 | 
|---|
| Flammability / Reaction to Fire | UL 1666 Riser | 
|---|
| CPR Compliance | CPR Euroclass: Eca | 
|---|
| NEC / UL Compliance | CMR, CL2R | 
|---|
| CEC / C(UL) Compliance | CMG | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
| Plenum Number | 3095A | 
|---|
Product Notes
| Notes | Tap marks every 2.6 meters to aid users in installation. | 
|---|