ControlBus™, Coax RG11 14AWG (Solid) Bare Copper Covered Steel, FEP Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 14 | Solid | BCCS - Bare Copper Covered Steel | 0.064 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| FEP - Fluorinated Ethylene Propylene (Foam) | 0.28 in |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Aluminum | | 60% |
| Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 4 | Aluminum | | 40% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PVDF - Polyvinylidene Fluoride | 0.387 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 11 Ohm/1000ft | 3.9 Ohm/1000ft | 3.9 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 16.5 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.097 µH/ft |
Impedance
| Nominal Characteristic Impedance | Nominal Characteristic Tolerance |
|---|
| 100 Ohm | ± 3 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.17 dB/100ft |
| 2 MHz | 0.22 dB/100ft |
| 5 MHz | 0.28 dB/100ft |
| 10 MHz | 0.4 dB/100ft |
| 20 MHz | 0.6 dB/100ft |
| 50 MHz | 1.2 dB/100ft |
| 100 MHz | 1.7 dB/100ft |
| 200 MHz | 2.5 dB/100ft |
| 300 MHz | 3.04 dB/100ft |
| 400 MHz | 3.5 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.2 ns/ft | 82% |
Phase Delay Distortion
| f/B | %PDD/100M (5MB) |
|---|
| 0.5 | -0.6 |
| 1 | -0.46 |
| 1.5 | 0 |
| 2 | 0.17 |
| 2.5 | 0.3 |
High Frequency
| Frequency [MHz] | Min. SRL (Structural Return Loss) |
|---|
| 1 MHz | 20 dB |
| 2 MHz | |
| 5 MHz | |
| 10 MHz | |
| 20 MHz | |
| 50 MHz | |
| 100 MHz | |
| 200 MHz | |
| 300 MHz | |
| 400 MHz | |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
| Electrical Characteristics Notes | Tilt 5 to 10 MHz: .42 dB/100 M |
|---|
| Other Electrical Characteristic 2 | Tilt 10 to 20 MHz: .58 dB/100 M |
|---|
| Other Electrical Characteristic 3 | SLR Min. 20dB (5MHz - 50MHz) |
|---|
Temperature Range
| UL Temp Rating | 150°C |
|---|
| Operating Temperature Range | -20°C To +150°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 68 lbs/1000ft |
|---|
| Max. Pull Tension | 309 lbs |
|---|
| Min. Bend Radius/Minor Axis | 4 in |
|---|
Standards
| NEC Articles | Article 800 |
|---|
| NEC/(UL) Compliance | CMP |
|---|
| CEC/C(UL) Compliance | CMP |
|---|
| RG Type | 11 |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Burial | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
Product Notes
| Notes | Sweep tested 5 to 400 MHz. Tap marks every 2.6 meters to aid users in installation. |
|---|
History
| Update and Revision | Revision Number: 0.303 Revision Date: 05-05-2023 |
|---|
Documentation
Catalogs
Technical Resources
Data Sheets