Belden

3095A - ControlBus™, Coax RG11, #14 Sol BCCS, FEP Ins, QUAD AL Shld, PVDF Jkt, CMP

(No reviews yet) Write a Review
SKU:
3095A
Shipping:
Calculated at Checkout
$0.00

Description

ControlBus™, Coax RG11 14AWG (Solid) Bare Copper Covered Steel, FEP Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNominal DiameterNo. of Coax
14SolidBCCS - Bare Copper Covered Steel0.064 in1
Conductor Count1

Insulation

MaterialNominal Diameter
FEP - Fluorinated Ethylene Propylene (Foam)0.28 in

Outer Shield

TypeLayerMaterialMaterial Trade NameCoverage [%]
Tape1Tri-Laminate (Alum+Poly+Alum)Duofoil®100%
Braid2Aluminum60%
Tape3Tri-Laminate (Alum+Poly+Alum)Duofoil®100%
Braid4Aluminum40%

Outer Jacket

MaterialNominal Diameter
PVDF - Polyvinylidene Fluoride0.387 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Outer Shield DCROuter Conductor DCR
11 Ohm/1000ft3.9 Ohm/1000ft3.9 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Shield
16.5 pF/ft

Inductance

Nominal Inductance
0.097 µH/ft

Impedance

Nominal Characteristic ImpedanceNominal Characteristic Tolerance
100 Ohm± 3 Ohm

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss
1 MHz0.17 dB/100ft
2 MHz0.22 dB/100ft
5 MHz0.28 dB/100ft
10 MHz0.4 dB/100ft
20 MHz0.6 dB/100ft
50 MHz1.2 dB/100ft
100 MHz1.7 dB/100ft
200 MHz2.5 dB/100ft
300 MHz3.04 dB/100ft
400 MHz3.5 dB/100ft

Delay

Nominal DelayNominal Velocity of Propagation (VP) [%]
1.2 ns/ft82%

Phase Delay Distortion

f/B%PDD/100M (5MB)
0.5-0.6
1-0.46
1.50
20.17
2.50.3

High Frequency

Frequency [MHz]Min. SRL (Structural Return Loss)
1 MHz20 dB
2 MHz
5 MHz
10 MHz
20 MHz
50 MHz
100 MHz
200 MHz
300 MHz
400 MHz

Voltage

UL Voltage Rating
300 V RMS
Electrical Characteristics NotesTilt 5 to 10 MHz: .42 dB/100 M
Other Electrical Characteristic 2Tilt 10 to 20 MHz: .58 dB/100 M
Other Electrical Characteristic 3SLR Min. 20dB (5MHz - 50MHz)

Temperature Range

UL Temp Rating150°C
Operating Temperature Range-20°C To +150°C

Mechanical Characteristics

Bulk Cable Weight68 lbs/1000ft
Max. Pull Tension309 lbs
Min. Bend Radius/Minor Axis4 in

Standards

NEC ArticlesArticle 800
NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP
RG Type11

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHS)Yes

Suitability

Suitability - BurialYes
Suitability - OutdoorYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)Yes

Related Part Numbers

Non-Plenum Number3094A

Product Notes

NotesSweep tested 5 to 400 MHz. Tap marks every 2.6 meters to aid users in installation.

History

Update and RevisionRevision Number: 0.303 Revision Date: 05-05-2023

Documentation

Catalogs

Technical Resources

Data Sheets

View AllClose