RS-485, 120 Ohm, 1 pair 22AWG (7x30) tinned copper Datalene® insulaton and a Foil Tape Shield, and 1conductor 22AWG (7x30) Tinned Copper, PVC Insulated conductor, Overall 65% Tinned Copper Braid, CPE jacket, CM, PLTC, SUN RES DIR BUR and oil-resistant
Specifications
Specifications
Product Overview
Suitable Applications | direct burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Conductor(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|
Pair(s) | PE - Polyethylene (Foam) | 0.033 in (0.84 mm) | 0.095 in (2.4 mm) | White/Orange Stripe & Orange/White Stripe | HDPE |
Conductor(s) | PVC - Polyvinyl Chloride | 0.017 in (0.43 mm) | 0.062 in (1.6 mm) | Blue/White Stripe | |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Braid | Tinned Copper (TC) | 65% | |
Waterblocking | Waterblock Tape |
---|
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
CPE - Chlorinated Polyethylene | 0.055 in (1.4 mm) | 0.359 in (9.12 mm) |
Overall Cable Diameter (Nominal) | 0.359 in (9.12 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
Pair(s) | 18.2 Ohm/1000ft | 11 pF/ft (36 pF/m) | 20.9 pF/ft | 120 Ohm | 78% | 6 Amps per Conductor at 30ºC |
Conductor(s) | 18.2 Ohm/1000ft (59.7 Ohm/km) | | | | | 6 Amps per Conductor at 30ºC |
Nom. Outer Shield DCR | 4.544 Ohm/1000ft (14.91 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
Pair(s) | 1 | 0.5 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM, PLTC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
60°C | -20°C to +60°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
4.308 in (109.4 mm) | 4.308 in (109.4 mm) |
Max. Pull Tension | 75.26 lbs (34.14 kg) |
---|
Bulk Cable Weight | 62 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
---|
Flammability / Reaction to Fire | UL 1685 UL Loading, IEC 60332-1-2 |
---|
NEC / UL Compliance | Article 725, Article 800, CM, PLTC |
---|
CEC / C(UL) Compliance | CM |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Oil Resistance: Passes Oil Res I & II Per UL1277, Table 10.17 |
---|
History
Update and Revision | Revision Number: 0.216 Revision Date: 04-14-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets