Security & Commercial Audio Cable, 6-22 AWG stranded bare copper conductors with Low Smoke Zero Halogen insulation, Beldfoil® shield and LSZH jacket with ripcord, CPR Cca
Specifications
Specifications
Product Overview
| Suitable Applications | Security System, Intercom/PA, Audio/Speaker, Power-Limited Controls, Noisy Environment |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
|---|
| 22 | 7x30 | BC - Bare Copper | 0.75 mm | 6 |
Insulation
| Type | Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| Insulation | LSZH - Low Smoke Zero Halogen (Flame Retardant) | 1.07 mm | 0.35 mm |
Color Chart
| Number | Color |
|---|
| Wire 1 | Black |
| Wire 2 | Red |
| White |
| Green |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 µm | TC - Tinned Copper | AWG24/7 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6.8 mm | 1.1 mm | Yes |
| Table Notes | Ripcord provided under sheath |
|---|
Construction and Dimensions
Cabling
| Description |
|---|
| 6 wires twisted |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|
| 54 Ohm/km | 54 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 105 pF/m | 185 pF/m |
Current
| Max. Recommended Current [A] |
|---|
| 2.0 Amps per Conductor |
Voltage
Temperature Range
| Installation Temperature Range | -20°C To +70°C |
|---|
| Storage Temperature Range | -30°C To +70°C |
|---|
| Operating Temperature Range | -20°C To +70°C |
|---|
Mechanical Characteristics
| Max. Pull Tension | 120 N |
|---|
| Min. Bend Radius During Installation | 68 mm |
|---|
| Min Setting Radius | 34 mm |
|---|
Standards
| CPR Euroclass | Cca-s1a,d1,a1 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Cca |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 80% |
|---|
History
| Update and Revision | Revision Number: 0.56 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets