Security & Commercial Audio Cable, 8-22 AWG stranded bare copper conductors with polypropylene insulation, LSZH jacket with ripcord, CPR Eca
Specifications
Specifications
Product Overview
| Suitable Applications | Security/Intercom/PA/Sound/Audio Systems,Power Limited Controls, Single Line Telephone; Commercial applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
|---|
| 22 | 7x30 | BC - Bare Copper | 0.75 mm | 8 |
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|
| Insulation | PE - Polyethylene | 1.07 mm | 0.05 mm | 0.2 mm |
Color Chart
| Number | Color |
|---|
| Wire 1 | Black |
| Wire 2 | Red |
| Wire 3 | White |
| Wire 4 | Green |
| Wire 5 | Brown |
| Wire 6 | Blue |
| Wire 7 | Orange |
| Wire 8 | Yellow |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 4.65 mm | 0.4 mm | Yes |
| Table Notes | Ripcord provided under sheath |
|---|
Construction and Dimensions
Cabling
| Description |
|---|
| 8 wires twisted |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 53 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor |
|---|
| 80 pF/m |
Current
| Max. Recommended Current [A] |
|---|
| 2 A |
Voltage
Temperature Range
| Installation Temperature Range | -20°C To +70°C |
|---|
| Storage Temperature Range | -30°C To +70°C |
|---|
| Operating Temperature Range | -20°C To +70°C |
|---|
Mechanical Characteristics
| Max. Pull Tension | 135 N |
|---|
| Min. Bend Radius During Installation | 46.5 mm |
|---|
| Min Setting Radius | 23.25 mm |
|---|
Standards
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Eca |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.228 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Solutions Guide
Tools
Data Sheets