Security & Commercial Audio Cable, 2-22 AWG stranded bare copper pairs with polypropylene insulation, Beldfoil® shield, LSZH jacket with ripcord, CPR Eca
Specifications
Specifications
Product Overview
| Suitable Applications | Security Systems, Intercom/PA Systems, Sound/Audio Systems, Power-Limited Controls | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs | 
|---|
| 22 | 7x30 | BC - Bare Copper | 0.75 mm | 2 | 
| Conductor Count | 4 | 
|---|
| Total Number of Pairs | 2 | 
|---|
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness | 
|---|
| Insulation | PE - Polyethylene | 1.07 mm | 0.05 mm | 0.2 mm | 
Color Chart
| Number | Color | 
|---|
| Pair 1 | Black & Red | 
| Pair 2 | Black & White | 
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 µm | TC - Tinned Copper | AWG24/7 | 
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 5.3 mm | 0.4 mm | Yes | 
| Table Notes | Ripcord provided under sheath | 
|---|
Construction and Dimensions
Cabling
| Description | 
|---|
| 2 pairs twisted | 
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | 
|---|
| 54 Ohm/km | 46 Ohm/km | 
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | 
|---|
| 105 pF/m | 190 pF/m | 
Current
| Max. Recommended Current [A] | 
|---|
| 2.2 Amps per Conductor | 
Voltage
Temperature Range
| Installation Temperature Range | -20°C To +70°C | 
|---|
| Storage Temperature Range | -30°C to +70°C | 
|---|
| Operating Temperature Range | -20°C To +70°C | 
|---|
Mechanical Characteristics
| Max. Pull Tension | 60 N | 
|---|
| Min. Bend Radius During Installation | 53 mm | 
|---|
| Min Setting Radius | 26.5 mm | 
|---|
Standards
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Eca | 
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 | 
|---|
| IEC 60754-1 - Halogen Amount | Zero | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 | 
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% | 
|---|