Security & Commercial Audio Cable, 3-22 AWG stranded bare copper pairs with polypropylene insulation, Beldfoil® shield, LSZH jacket with ripcord, CPR Eca
Specifications
Specifications
Product Overview
Suitable Applications | Security System, Intercom/PA, Audio/Speaker, Power-Limited Controls, Noisy Environment |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
22 | 7x30 | BC - Bare Copper | 0.75 mm | 3 |
Conductor Count | 6 |
---|
Total Number of Pairs | 3 |
---|
Insulation
Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
---|
Insulation | PP - Polypropylene | 1.07 mm | 0.05 mm | 0.2 mm |
Color Chart
Number | Color |
---|
Pair 1 | Black & Red |
Pair 2 | Black & White |
Pair 3 | Black & Green |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 µm | TC - Tinned Copper | AWG24/7 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 5.3 mm | 0.4 mm | Yes |
Table Notes | Ripcord provided under sheath |
---|
Construction and Dimensions
Cabling
Description |
---|
3 pairs twisted |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
54 Ohm/km | 46 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
80 pF/m | 140 pF/m |
Current
Max. Recommended Current [A] |
---|
2.0 Amps per Conductor |
Voltage
Temperature Range
Installation Temperature Range | -20°C To +70°C |
---|
Storage Temperature Range | -30°C to +70°C |
---|
Operating Temperature Range | -20°C To +70°C |
---|
Mechanical Characteristics
Max. Pull Tension | 130 N |
---|
Min. Bend Radius During Installation | 53 mm |
---|
Min Setting Radius | 27 mm |
---|
Standards
Applicable Environmental and Other Programs
Environmental Space | Indoor - Euroclass Eca |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
History
Update and Revision | Revision Number: 0.13 Revision Date: 02-23-2023 |
---|
Documentation
Product Bulletins
Solutions Guide
Tools
Data Sheets