Security & Commercial Audio Cable, 3-22 AWG solid bare copper pairs with polypropylene insulation, Beldfoil® shield, LSZH jacket with ripcord
Specifications
Specifications
Product Overview
| Suitable Applications | Security/Intercom/PA/Sound/Audio Systems,Power-Limited Controls | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs | 
|---|
| 22 | Solid | BC - Bare Copper | 0.64 mm | 3 | 
| Conductor Count | 6 | 
|---|
| Total Number of Pairs | 3 | 
|---|
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness | 
|---|
| Insulation | PE - Polyethylene | 1.07 mm | 0.05 mm | 0.2 mm | 
Color Chart
| Number | Color | 
|---|
| Pair 1 | Black & Red | 
| Pair 2 | Black & White | 
| Pair 3 | Black & Green | 
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 µm | TC - Tinned Copper | AWG24 | 
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 4.9 mm | 0.4 mm | Yes | 
| Table Notes | Ripcord provided under sheath | 
|---|
Construction and Dimensions
Cabling
| Description | 
|---|
| 3 pairs twisted | 
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | 
|---|
| 52 Ohm/km | 46 Ohm/km | 
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | 
|---|
| 100 pF/m | 180 pF/m | 
Current
| Max. Recommended Current [A] | 
|---|
| 2 A | 
Voltage
Temperature Range
| Installation Temperature Range | -20°C To +70°C | 
|---|
| Storage Temperature Range | -30°C to +70°C | 
|---|
| Operating Temperature Range | -20°C To +70°C | 
|---|
Mechanical Characteristics
| Max. Pull Tension | 100 N | 
|---|
| Min. Bend Radius During Installation | 49 mm | 
|---|
| Min Setting Radius | 24.5 mm | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor | 
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 | 
|---|
| IEC 60754-1 - Halogen Amount | Zero | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 | 
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% | 
|---|
History
| Update and Revision | Revision Number: 0.215    Revision Date: 11-09-2022 | 
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets