Description

PTZ (CCTV + Control + Power) Cable, Riser-CMR, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-18 AWG stranded bare copper pair with polyolefin insulation and Beldfoil® shield, 2-18 AWG stranded bare copper conductors with polyolefin insulation, Siamese with PVC jacket

Specifications

Specifications

Product Overview

Suitable ApplicationsSurveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom)

Physical Characteristics (Overall)

Conductor

ElementAWGStrandingMaterialNominal DiameterNo. of ConductorsNo. of Coax
Coax(es)20SolidBC - Bare Copper0.032 in1
Pair11819x30BC - Bare Copper0.044 in2
Pair2187x26BC - Bare Copper0.047 in2
Conductor Count5

Insulation

ElementMaterialNominal DiameterNominal Wall Thickness
Coax(es)PE - Polyethylene (Foam)0.145 in
Pair1PP - Polypropylene0.08 in
Pair2PP - Polypropylene0.0065 in
Table NotesGas Injected

Color Chart

NumberColor
Coax CoreWhite
Pair1Blue & White/Blue
Pair2Black & Red

Color Chart 4

NumberColor
Coax JacketBlack
Pair1 JacketBlue
Pair2 JacketWhite

Inner Shield

ElementTypeMaterialMaterial Trade NameCoverage [%]
Coax(es)BraidBare Copper (BC)95%
Pair1TapeBi-Laminate (Alum+Poly)Beldfoil®100%
Pair2No Shield

Inner Jacket

MaterialNominal DiameterNominal Wall Thickness
PVC - Polyvinyl Chloride0.227 in0.030 in
PVC - Polyvinyl Chloride0.219 in0.028 in
PVC - Polyvinyl Chloride0.158 in0.020 in

Outer Shield

Drainwire Construction n x D
7x28

Outer Jacket

MaterialNominal Diameter
Banana Peel (No Overall Jacket)0.451 in
0.219 in
0.158 in
0.451 in

Electrical Characteristics

Conductor DCR

ElementNominal Conductor DCRNominal Conductor DCR Conductor ResistanceNominal Inner Shield DCR
Coax(es)10 Ohm/1000ft10 Ohm/1000ft3.5 Ohm/1000ft
Pair16.5 Ohm/1000ft6.5 Ohm/1000ft
Pair26.5 Ohm/1000ft6.5 Ohm/1000ft

Capacitance

ElementNom. Capacitance Conductor to ConductorNom. Capacitance Conductor to Shield
Coax(es)16.3 pF/ft
Pair126 pF/ft44 pF/ft
Pair221.5 pF/ft

Impedance

ElementNominal Characteristic Impedance
Coax(es)75 Ohm

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss
1 MHz0.3 dB/100ft
5 MHz0.65 dB/100ft
10 MHz0.9 dB/100ft
50 MHz1.9 dB/100ft
100 MHz2.6 dB/100ft
200 MHz3.6 dB/100ft
400 MHz5 dB/100ft
700 MHz7 dB/100ft
900 MHz8 dB/100ft
1000 MHz8.5 dB/100ft

Delay

ElementMax. Delay SkewNominal DelayNominal Velocity of Propagation (VP) [%]
Coax(es)83 ns/100m1.22 ns/ft83%

Current

ElementMax. Recommended Current [A]
Coax(es)
Pair15 Amps per Conductor at 25ºC
Pair2

Voltage

UL Voltage Rating
300 V RMS

Temperature Range

Installation Temperature Range0°C To +75°C
UL Temp Rating75°C
Operating Temperature Range-10°C To +75°C
Separation Temp Range0°C To +75°C

Mechanical Characteristics

Bulk Cable Weight74 lbs/1000ft
Max. Pull Tension140 lbs

Standards

NEC ArticlesArticle 800
NEC/(UL) ComplianceCMR
CPR EuroclassFca
RG Type59
Other SpecificationVideo coax: RG 59/U

Applicable Environmental and Other Programs

Environmental SpaceIndoor - Riser
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceYes
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Suitability

Suitability - IndoorYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1666 Vertical Shaft
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No
Plenum Number602PTZ

Related Part Numbers

PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Product Notes

NotesRG59 CCTV + 1 STP18 AWG Control Grade + 2C 18 AWG CMR. Individually jacketed and color coded components, cabled around and each fused to a central binding spline. Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation.

History

Update and RevisionRevision Number: 0.358 Revision Date: 05-05-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|UPC
Variant_Options 502PTZ 0001000:
502PTZ 0001000|Black, Blue, White|612825155850
Variant_Options 502PTZ 000500:
502PTZ 000500|Black, Blue, White|612825155867
View AllClose