Surveillance and CCTV Cable, Coax RG11/U, Solid bare copper, gas injected polyethylene, 95% bare copper braid, PVC innerjacket, 90% Single steel wire armouring, PVC jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Coaxial cable used in analogue video and CCTV communication networks designed according European Standard EN 50117-1; Operating frequencies between 5 and 1000 MHz |
|---|
Construction Details
Conductor
| Number of Element | Size | Stranding | Nom. Diameter | Material |
|---|
| 1 | 14 AWG | Solid | 1.63 mm | BC - Bare Copper |
Insulation
| Material | Nom. Insulation Diameter |
|---|
| PE - Polyethylene (Foam) | 7.11 mm (0.280 in) |
Inner Shield
| Shield Type | Material |
|---|
| Braid | Bare Copper (BC) |
Inner Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 10.3 mm (0.406 in) |
Outer Shield
| Outer Shield Type | Material | Coverage |
|---|
| Braid | Bare Copper (BC) | 95% |
Armor
| Armor Type & Material | Armor Thickness | Coverage |
|---|
| SWA - Steel Wire Armor | 1.25 mm (0.0492 in) | 90% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 15.6 mm |
Electrical Characteristics
Return Loss
| Frequency | Min. Return Loss |
|---|
| 5 - 30 MHz | 23 dB |
| 30 - 470 MHz | 23 dB |
| 470 - 1000 MHz | 20 dB |
| Table Notes | In each frequency band, 3 peak values up to 4 dB lower are allowed |
|---|
Attenuation
| Frequency | Nom. Attenuation |
|---|
| 1 MHz | 0.56 dB/100m |
| 10 MHz | 1.15 dB/100m |
| 50 MHz | 2.95 dB/100m |
| 100 MHz | 4.26 dB/100m |
| 200 MHz | 6.20 dB/100m |
| 400 MHz | 9.5 dB/100m |
| 700 MHz | 13.5 dB/100m |
| 900 MHz | 15.8 dB/100m |
| 1000 MHz | 17.1 dB/100m |
| Table Notes | Max. attenuation 10% higher |
|---|
Electricals
| Max. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|
| 8.5 Ohm/km (2.6 Ohm/1000ft) | 3.9 Ohm/km (1.2 Ohm/1000ft) | 53 pF/m (16 pF/ft) | 75 Ohm | 84% |
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|
| -30°C To +75°C | -5°C To +50°C | -30°C To +75°C |
Bend Radius
| Stationary Min. |
|---|
| 101 mm (3.98 in) |
| Bulk Cable Weight | 486 kg/km |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor |
|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
|---|
| CENELEC Compliance | EN 50117-1EN 50117-9-1EN 50290-2-20 |
|---|
History
| Update and Revision | Revision Number: 0.197 Revision Date: 03-30-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Compliance Documentation
Data Sheets