Security & Commercial Audio Cable, 3 Conductor 16 AWG stranded (19x29) tinned copper conductors with polyolefin insulation, Beldfoil® shield, PVC jacket with ripcord, Riser rated.
Specifications
Specifications
Product Overview
Suitable Applications | Intercom/PA Systems, Sound/Audio Systems |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
---|
16 | 19x29 | TC - Tinned Copper | 0.059 in | 3 |
Insulation
Material | Nominal Diameter |
---|
PP - Polypropylene | 0.075 in |
Color Chart
Number | Color |
---|
1 | Black |
2 | Red |
3 | White |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.020 in | 24 |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.199 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
4 Ohm/1000ft | 15.2 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
58 pF/ft | 104.5 pF/ft |
Current
Max. Recommended Current [A] |
---|
6.25 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 75°C |
---|
Operating Temperature Range | -5°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 36 lbs/1000ft |
---|
Max. Pull Tension | 89 lbs |
---|
Min. Bend Radius/Minor Axis | 2.00 in |
---|
Standards
NEC Articles | Article 800 |
---|
NEC/(UL) Compliance | CMR |
---|
CEC/C(UL) Compliance | CMG |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
Suitability
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1666 Vertical Shaft |
---|
Plenum/Non-Plenum
Plenum (Y/N) | No |
---|
Plenum Number | 6201FH |
---|
Product Notes
Notes | Print legend includes sequential footage marks. Rip cord under jacket. |
---|
History
Update and Revision | Revision Number: 0.60 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets