PTZ Cable, Rated-CM, 1-22 AWG tinned copper pair with PVC insulation and a Beldfoil® shield, 1-22 AWG tinned copper conductor with PVC insulation, overall water resistant tape and PVC jacket with ripcord
Specifications
Specifications
Product Overview
| Suitable Applications | Security System, Intercom/PA, Audio/Speaker, Power-Limited Controls, Noisy & Wet Location, Below-Grade Duct |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Pair(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
| Conductor(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Pair(s) | PVC - Polyvinyl Chloride | 0.01 in (0.25 mm) | 0.051 in (1.3 mm) | Black and Red |
| Conductor(s) | PVC - Polyvinyl Chloride | 0.01 in (0.25 mm) | 0.051 in (1.3 mm) | White |
Inner Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
| No Shield | | |
| Table Notes | Waterblocking tape |
|---|
| Waterblocking | Waterblock Tape |
|---|
Outer Jacket
| Separator | Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|
| Waterblocking Tape | PVC - Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.222 in | Yes |
| Overall Cable Diameter (Nominal) | 0.222 in |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
|---|
| Pair(s) | 16.4 Ohm/1000ft | 14.5 Ohm/1000ft (47.6 Ohm/km) | 44.5 pF/ft (146 pF/m) | 80.1 pF/ft (263 pF/m) | 5 Amps per Conductor at 25ºC |
| Conductor(s) | 17.9 Ohm/1000ft (58.7 Ohm/km) | | | | 5 Amps per Conductor at 25ºC |
Voltage
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 105°C | -40°C To +105°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 2.22 in (56.4 mm) | 2.22 in |
| Max. Pull Tension | 32.8 lbs (14.9 kg) |
|---|
| Bulk Cable Weight | 21 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
|---|
| Flammability / Reaction to Fire | UL1685 UL Loading, IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | Article 800, CM |
|---|
| CEC / C(UL) Compliance | CM |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.308 Revision Date: 05-05-2023 |
|---|
Documentation
Brochures and Guides
All Resources
Compliance Documentation
Data Sheets