Belden

5501G1 - Security & Sound, #22-1pr, #22-1c TC, Shielded Pair, CM, Water-Blocked

(No reviews yet) Write a Review
SKU:
5501G1
Shipping:
Calculated at Checkout
$0.00

Description

PTZ Cable, Rated-CM, 1-22 AWG tinned copper pair with PVC insulation and a Beldfoil® shield, 1-22 AWG tinned copper conductor with PVC insulation, overall water resistant tape and PVC jacket with ripcord

Specifications

Specifications

Product Overview

Suitable ApplicationsSecurity System, Intercom/PA, Audio/Speaker, Power-Limited Controls, Noisy & Wet Location, Below-Grade Duct

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)122 AWG7x30TC - Tinned Copper
Conductor(s)122 AWG7x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Pair(s)PVC - Polyvinyl Chloride0.01 in (0.25 mm)0.051 in (1.3 mm)Black and Red
Conductor(s)PVC - Polyvinyl Chloride0.01 in (0.25 mm)0.051 in (1.3 mm)White

Inner Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%24 AWG (7x32) TC
No Shield
Table NotesWaterblocking tape
WaterblockingWaterblock Tape

Outer Jacket

SeparatorMaterialNom. ThicknessNom. DiameterRipcord
Waterblocking TapePVC - Polyvinyl Chloride0.025 in (0.64 mm)0.222 inYes
Overall Cable Diameter (Nominal)0.222 in

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Inner Shield DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Max. Current
Pair(s)16.4 Ohm/1000ft14.5 Ohm/1000ft (47.6 Ohm/km)44.5 pF/ft (146 pF/m)80.1 pF/ft (263 pF/m)5 Amps per Conductor at 25ºC
Conductor(s)17.9 Ohm/1000ft (58.7 Ohm/km)5 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating
300 V

Mechanical Characteristics

Temperature

UL TemperatureOperating
105°C-40°C To +105°C

Bend Radius

Stationary Min.Installation Min.
2.22 in (56.4 mm)2.22 in
Max. Pull Tension32.8 lbs (14.9 kg)
Bulk Cable Weight21 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 800, CM
CEC / C(UL) ComplianceCM
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.308 Revision Date: 05-05-2023

Documentation

Brochures and Guides

All Resources

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|UPC
Variant_Options 5501G1 0101000:
5501G1 0101000|Black|612825163237
Variant_Options 5501G1 0081000:
5501G1 0081000|Gray|612825163220
View AllClose