Description

UL Instrumentation, 4 Pair 12AWG (7x20) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC 150V NPLF THHN OR THWN 90C Dry 75C Wet SUN RES DIR BUR

Specifications

Specifications

Put-Up TypeReel

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNominal DiameterNo. of Pairs
127x20BC - Bare Copper0.089 in4
Conductor Count8

Insulation

MaterialNominal DiameterNominal Wall Thickness
PVC/Nylon - Polyvinyl Chloride + Nylon0.131 in0.021 in

Color Chart

NumberColor
Pair 1Black and White Numbered 1
Pair 2Black and White Numbered 2
Pair 3Black and White Numbered 3
Pair 4Black and White Numbered 4

Inner Shield

ElementTypeMaterialMaterial Trade NameCoverage [%]Drainwire MaterialDrainwire DiameterDrainwire AWG
Each PairTapeBi-Laminate (Alum+Poly)Beldfoil®100%TC - Tinned Copper0.052 in16

Outer Shield

TypeMaterialMaterial Trade NameCoverage [%]Drainwire MaterialDrainwire DiameterDrainwire AWG
TapeBi-Laminate (Alum+Poly)Beldfoil®100%TC - Tinned Copper0.052 in16

Outer Jacket

MaterialNominal DiameterNominal Wall Thickness
PVC - Polyvinyl Chloride0.723 in0.063 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Inner Shield DCRNominal Outer Shield DCR
1.65 Ohm/1000ft6.24 Ohm/1000ft1.56 Ohm/1000ft

Current

Max. Recommended Current [A]
15 Amps per Conductor at 30ºC

Voltage

UL DescriptionUL Voltage Rating
TC
NPLF150 V RMS (NPLF)

Temperature Range

UL Temp Rating90°C Wet/Dry
Operating Temperature Range-25°C To +90°C

Mechanical Characteristics

Bulk Cable Weight337 lbs/1000ft
Max. Pull Tension694 lbs
Min Bend Radius (Overall)7.25 in
Min. Bend Radius/Minor Axis7.2 in

Standards

NEC/(UL) ComplianceNPLF, TC, THHN/THWN

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
CA Prop 65Yes

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

CSA/C(UL) FlammabilityFT4
UL FlammabilityUL1685 UL Loading
IEEE Flammability1202
UL voltage rating600 V RMS (Type TC)

Product Notes

NotesAlternate color coding available upon request.

History

Update and RevisionRevision Number: 0.36 Revision Date: 04-14-2023
View AllClose