UL Type TC (1277) VN/PVC, 2 Triad 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | No. of Triads |
|---|
| Conductor(s) | 18 | 7x26 | BC - Bare Copper | 2 |
Insulation
| Material | Nominal Diameter |
|---|
| PVC/Nylon - Polyvinyl Chloride + Nylon | 0.087 in |
Color Chart
| Number | Color |
|---|
| 1 | Black, White & Red and Numbered 1 |
| 2 | Black, White & Red and Numbered 2 |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.471 in | 0.047 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 5.86 Ohm/1000ft |
Current
| Max. Recommended Current [A] |
|---|
| 4.8 Amps per Conductor at 30ºC |
Voltage
| Description | UL Description | UL Voltage Rating | Voltage Rating [V] |
|---|
| Type TC | TC | 600 V RMS (Type TC) | 600 V RMS (Type TC) |
| NPLF | 150 V RMS (NPLF) | |
Temperature Range
| UL Temp Rating | 75°C Wet, 90°C Dry |
|---|
| Operating Temperature Range | -30°C To +90°C |
|---|
Mechanical Characteristics
| UV Resistance | Yes |
|---|
| Bulk Cable Weight | 97 lbs/1000ft |
|---|
| Max. Pull Tension | 78 lbs |
|---|
| Min. Bend Radius/Minor Axis | 4.71 in |
|---|
Standards
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
Suitability
| Suitability - Burial | Yes |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL 1685 UL Loading |
|---|
| IEEE Flammability | IEEE 1202 |
|---|
| UL voltage rating | 600 V RMS (Type TC) |
|---|