PTZ (CCTV + Power/Audio) Cable, Plenum-CMP, 1-RG6 18 AWG solid bare copper with foam FEP, 95% bare copper braid, 1-18 AWG stranded bare copper pair with Flamarrest® insulation, Siamese with Flamarrest® jacket
Specifications
Specifications
Product Overview
Suitable Applications | Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom) |
---|
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | Nominal Diameter | No. of Conductors | No. of Coax |
---|
Coax(es) | 18 | Solid | BC - Bare Copper | | | 1 |
Pair1 | 18 | 7x26 | BC - Bare Copper | 0.047 in | 2 | |
Insulation
Element | Material | Nominal Diameter |
---|
Coax(es) | PE - Polyethylene (Foam) | 0.170 in |
Pair1 | PVC - Polyvinyl Chloride | 0.062 in |
Color Chart
Number | Color |
---|
Coax Core | White |
Pair1 | Black & Red |
Inner Shield
Element | Type | Material | Coverage [%] |
---|
Coax(es) | Braid | Bare Copper (BC) | 95% |
Pair1 | | No Shield | |
Inner Jacket
Outer Jacket
Material | Material Trade Name | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | Flamarrest® | 0.230 in x 0.424 in |
Construction and Dimensions
OuterJacket1, Nominal Width | 0.0394 in |
---|
Electrical Characteristics
Conductor DCR
Element | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR |
---|
Coax(es) | 6.4 Ohm/1000ft | 6.4 Ohm/1000ft | 2.2 Ohm/1000ft |
Pair1 | | | |
Capacitance
Element | Nom. Capacitance Conductor to Conductor |
---|
Coax(es) | 16.1 pF/ft |
Pair1 | |
Impedance
Element | Nominal Characteristic Impedance |
---|
Coax(es) | 75 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] |
---|
1 MHz |
5 MHz |
10 MHz |
50 MHz |
100 MHz |
200 MHz |
400 MHz |
700 MHz |
900 MHz |
1000 MHz |
Delay
Element | Max. Delay Skew | Nominal Delay |
---|
Coax(es) | 84 ns/100m | 1.21 ns/ft |
Current
Temperature Range
Installation Temperature Range | 0°C To +75°C |
---|
UL Temp Rating | 75°C |
---|
Operating Temperature Range | 0°C To +75°C |
---|
Separation Temp Range | 0°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 55 lbs/1000ft |
---|
Max. Pull Tension | 89 lbs |
---|
Standards
NEC Articles | Article 800 |
---|
NEC/(UL) Compliance | CMP |
---|
CEC/C(UL) Compliance | CMP |
---|
CPR Euroclass | Eca |
---|
RG Type | 6 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Plenum |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
CSA/C(UL) Flammability | FT6 |
---|
UL Flammability | NFPA 262 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Product Notes
Notes | 18 AWG pair is unshielded |
---|
History
Update and Revision | Revision Number: 0.504 Revision Date: 07-19-2023 |
---|
Documentation
Product Bulletins
Catalogs
Data Sheets