PTZ (CCTV + Power/Audio) Cable, Plenum-CMP, 1-RG59 20 AWG solid bare copper with foam FEP, 95% bare copper braid, 1-18 AWG stranded bare copper pair with Flamarrest® insulation, Siamese with Flamarrest® jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom) |
|---|
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | Nominal Diameter | No. of Conductors | No. of Coax |
|---|
| Coax(es) | 20 | Solid | BC - Bare Copper | | | 1 |
| Pair1 | 18 | 7x26 | BC - Bare Copper | 0.047 in | 2 | |
Insulation
| Element | Material | Nominal Diameter |
|---|
| Coax(es) | PE - Polyethylene (Foam) | 0.133 in |
| Pair1 | PVC - Polyvinyl Chloride | 0.062 in |
Color Chart
| Number | Color |
|---|
| Coax Core | White |
| Pair1 | Black & Red |
Inner Shield
| Element | Type | Material | Coverage [%] |
|---|
| Coax(es) | Braid | Bare Copper (BC) | 95% |
| Pair1 | | No Shield | |
Inner Jacket
Outer Jacket
| Material | Material Trade Name | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | Flamarrest® | 0.192 in x 0.383 in |
Electrical Characteristics
Conductor DCR
| Element | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Outer Conductor DCR |
|---|
| Coax(es) | 10 Ohm/1000ft | 10 Ohm/1000ft | 2.5 Ohm/1000ft | 2.5 Ohm/1000ft |
| Pair1 | | | | |
Capacitance
| Element | Nom. Capacitance Conductor to Conductor |
|---|
| Coax(es) | 16.1 pF/ft |
| Pair1 | |
Impedance
| Element | Nominal Characteristic Impedance |
|---|
| Coax(es) | 75 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | .29 dB/100ft |
| 5 MHz | 0.7 dB/100ft |
| 10 MHz | 1.1 dB/100ft |
| 50 MHz | 1.8 dB/100ft |
| 100 MHz | 2.7 dB/100ft |
| 200 MHz | 3.9 dB/100ft |
| 400 MHz | 5.9 dB/100ft |
| 700 MHz | 8.5 dB/100ft |
| 900 MHz | 10 dB/100ft |
| 1000 MHz | 10.7 dB/100ft |
Delay
| Element | Max. Delay Skew | Nominal Delay |
|---|
| Coax(es) | 84 ns/100m | 1.21 ns/ft |
Current
Temperature Range
| Installation Temperature Range | 0°C To +75°C |
|---|
| UL Temp Rating | 75°C |
|---|
| Operating Temperature Range | 0°C To +75°C |
|---|
| Separation Temp Range | 0°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 45 lbs/1000ft |
|---|
| Max. Pull Tension | 75 lbs |
|---|
Standards
| NEC Articles | Article 800 |
|---|
| NEC/(UL) Compliance | CMP |
|---|
| CEC/C(UL) Compliance | CMP |
|---|
| CPR Euroclass | Eca |
|---|
| RG Type | 59 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Plenum |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Burial | No |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT6 |
|---|
| UL Flammability | NFPA 262 |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Non-Plenum Number | 549945 |
|---|
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
| Notes | 18 AWG pair is unshielded |
|---|
History
| Update and Revision | Revision Number: 0.525 Revision Date: 07-19-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Data Sheets